Frequently Asked Questions

Limit Switch Topic: Connectors for Limit Switch

 

FAQ No. FAQ02140

 

Question

 

What connectors should be used for Limit Switches?


 

Answer


SC-series Connectors are available. Select the Connector according to the size of the conduit port and the external diameter of the cable to be used.

Metal Connectors

 

Conduit port

Applicable cable

Inner diameter (D)
of seal rubber

External diameter
of cable

O-ring

Model

Applicable model

Min.

Max.

JIS B 0202
G1/2

Cabtire (general-purpose)

7 dia. mm

5.5 dia. mm

7.5 dia. mm

Yes

SC-1M

WL, D4A-[]N, ZE, ZV, ZV2, VB, D4B-[]N

9 dia. mm

7.5 dia. mm

9.5 dia. mm

SC-2M

12.5 dia. mm

11 dia. mm

13 dia. mm

SC-3M

14 dia. mm

12 dia. mm

14 dia. mm

SC-4M

11 dia. mm

9 dia. mm

11 dia. mm

SC-5M

Cabtire (anticorrosive)

7 dia. mm

5.5 dia. mm

7.5 dia. mm

No

SC-21

9 dia. mm

7.5 dia. mm

9.5 dia. mm

SC-22

12.5 dia. mm

11 dia. mm

13 dia.  mm

SC-23

14 dia. mm

12 dia. mm

14 dia. mm

SC-24

11 dia. mm

9 dia. mm

11 dia. mm

SC-25

JIS B 0202
G3/4

Cabtire 13 10 13.5 Yes SC-31

DL

17.5 13.5 18 SC-32
22.3 18 22 SC-33

1/2-14NPT

Cabtire

7 dia. mm

5.5 dia. mm

7.5 dia. mm

No

SC-1PT

D4A-[]N, WL-[]-TS

9 dia. mm

7.5 dia. mm

9.5 dia. mm

SC-2PT

12.5 dia. mm

11 dia. mm

13 dia. mm

SC-3PT

14 dia. mm

12 dia. mm

14 dia. mm

SC-4PT

11 dia. mm

9 dia. mm

11 dia. mm

SC-5PT

 

Note:

1. No O-ring: Penetration of oil and water is not prevented. Use the Connector with sealing tape. O-ring: Penetration of oil and water is prevented.

 

2. Use an SC-P2 Rubber Ring and conduit washer for SC-21 to SC-25 Connectors.

 

3. SC-series Connectors must be used with sealing tape. SC-1M to SC-5M Connectors, however, include an NBR O-ring that ensures sealing without using sealing tape.

 


Dimensions and Structure (Unit: mm)
 

Metal Connectors

No O-ring

G1/2
SC-21 to 25

Metal Models without O-ring, G1/2, SC-21 to 25


Metal Connectors

O-ring
G1/2
SC-1M to 5M

Metal Models with O-ring, G1/2, SC-1M to 5M

 

Metal Connectors

No O-ring

G3/4
SC-31 to 33

 


Metal Connectors

No O-ring
1/2-14NPT
(U.S.-standard threaded screws)
SC-1PT to SC-5PT

Metal Models without O-ring, 1/2-14NPT, SC-1PT to 5PT
 

Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
*Diameter of Part Marked with Asterisk

 

Model

Inner diameter (D)
of sealed rubber

Internal diameter
(E) of washer

Applicable cable

SC-21, -1M, -1PT

7 dia.

10.4 dia.

5.5 to 7.5 dia.

SC-22, -2M, -2PT

9 dia.

13.2 dia.

7.5 to 9.5 dia.

SC-23, -3M, -3PT

12.5 dia.

14.6 dia.

11 to 13 dia.

SC-24, -4M, 4PT

14 dia.

14.6 dia.

12 to 14 dia.

SC-25, -5M, -5PT

11 dia.

13.2 dia.

9 to 11 dia.

SC-31

13 dia.

18.5 dia.

10 to 13.5 dia.

SC-32

17.5 dia.

18.5 dia.

13.5 to 18 dia.

SC-33

22.3 dia.

22.5 dia.

18 to 22 dia.



Simple Connectors

(Simple Connectors are made of resin, and so are not appropriate for environments subject to oil or water.)

 

Conduit Applicable cable Inner diameter (D)
of seal rubber
External diameter
of cable
Model Applicable model
Min. Max.
JIS B 0202
G1/2
Cabtire cable 10.6 dia. mm 8.5 dia. mm 10.5 dia. mm SC-P2 WL, D4A-[]N, ZE, ZV, D4B-[]N, VB
Pg13.5 9.6 dia. mm 7.5 dia. mm 9.5 dia. mm SC-P3

WL[]-G, D4B-[]N

JIS B 0202
G1/2
9 dia. mm 7.5 dia. mm 9 dia. mm SC-6

WL, D4A-[]N, D4N*, D4N-[]R*, D4B-[]N


Note: The casings for SC-P2, -P3 and -6 are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.

 

Resin Connectors
G1/2
SC-P2

Resin Models, G1/2, SC-P2


Resin Connectors
Pg13.5
SC-P3

Resin Models, Pg13.5, SC-P3


Resin Connectors
G1/2
SC-6

Resin Models, G1/2, SC-6


Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
*Diameter of Part Marked with Asterisk

 

FA Connectors

The connectors can be mounted and replaced easily, and they provide IP67 protection. For connection, use a cable with connectors.

 

Diagram: FA Connector Limit Switch, FA Connector, Connecting Cable


 

FA Connectors

 
Model Number of
conductors
Voltage
specification
Size of
conduit
Size of crimp
terminal
Applicable
model
SC-2F 2 125 VDC JIS B 0202
G1/2
M4 WL
SC-2FAD 2 250 VAC
SC-4F4D 4 125 VDC
SC-4F4AD 4 250 VAC

 

Other Cables

 

Staight Cable

 

Voltage
specification
Number of
conductors
Cable length Model
AC 2 2 m XS2F-A421-DB0-A
5 m XS2F-A421-GB0-A
4 2 m XS2F-A421-D90-A
5 m XS2F-A421-G90-A
DC 2 2 m XS2F-D421-DD0
5 m XS2F-D421-GD0
4 2 m XS2F-D421-D80-A
5 m XS2F-D421-G80-A

 

Note: Refer to XS2 Sensor I/O Connector (M12) for details.

 

 

Other Limit Switch FAQs

 What degree of protection is provided against water?

 Are holding Limit Switches available?

 Can the actuator of the WL be mounted on other Limit Switches?