Contact Displacement Sensor
last update: December 27, 2013
Agency | Standard | File No. |
---|---|---|
TÜV Product Service | EN61010-1 | Z1030339656046 |
UL | UL50 | E104818 |
Model number
(of set) |
D5SN-S01 | D5SN-S04 | D5SN-S04-L | D5SN-M05 | D5SN-M10 |
---|---|---|---|---|---|
Measurement range | 1 mm | 4 mm | 5 mm | 10 mm | |
Max. actuator travel
distance |
Approx. 1.5 mm | Approx. 5 mm | Approx. 6 mm | Approx. 12 mm | |
Resolution (See note 2.) | 0.1 μm | 0.4 μm | 0.5 μm | 1μm | |
Linearity (See note 3.) | 0.3% FS max. | 0.5% FS max. | 0.5% FS max. | ||
Repeat accuracy | 0.5 μm max. | 1.6 μm max. | 10 μm max. | 20 μm max. | |
Response time (not
including bounce time) |
100 ms max. | 200 ms max. | 300 ms max. | ||
Operating force
(See note 4.) |
Approx. 0.7 N | Approx. 0.25 N | 5 N max. | ||
Degree of protection (not
including the connector) |
IP67 | IP54 | IP67 | ||
Mechanical durability | 10,000,000 operations min. | ||||
Insulation/non-insulation
of mounting part |
Insulated | ||||
Ambient operating
temperature |
-10 to 60 °C (with no icing or condensation) | ||||
Ambient operating
humidity |
25% to 95% (with no condensation) | ||||
Temperature influence
(See note 5.) |
0.025% FS/°C | 0.010% FS/°C | 0.03% FS/°C | ||
Weight | Approx. 70 g (including cable connector) | Approx. 230 g | Approx. 300 g | ||
Connection cable length | 3-conductor shielded cable, 2 m |
Note:
1. The above figures are for use with the standard actuator.
2. These figures are the smallest values that can be read when using OMRON’s K3NX Process Meter.
3. “FS” refers to the corresponding measurement range.
4. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or vertically, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
5. These figures are representative values that apply for the mid-point of the measurement range.
Model | D5SN-A01 | |
---|---|---|
Supply voltage (allowable range) | 12 to 24 VDC (10.8 to 26.4 VDC) | |
Current consumption | 80 mA max. | |
Analog output
(See note 1.) |
Voltage | -5 to 5 V (load impedance: 10 kΩ min.) |
Current | 4 to 20 mA (load impedance: 300 Ω max.) | |
Enable output | Output form | NPN open collector |
Output switching
current |
100 mA max. | |
ON output residual
voltage |
1.5 V max. | |
OFF collector
dielectric strength |
26.4 VDC | |
OFF leakage current | 0.1 mA max. | |
Degree of protection | IP30 | |
Ambient operating temperature | -10 to 55 °C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% (with no condensation) | |
Temperature influence (See note 2.) | 0.010% FS/°C | |
Weight | Approx. 200 g (including the cable) | |
Connection cable length | 2-m-long, 5-conductor shielded cable |
Note:
1. Depending on the offset adjustment and span adjustment, analog output may leave the specified range (−5 to 5 V or 4 to 20 mA) even for values within the specified measurement range.
2. These figures are representative values that apply for the mid-point of the measurement range.
last update: December 27, 2013