Approved Standards

Agency Standard File No.
TÜV Product Service EN61010-1 Z1030339656046
UL UL50 E104818

Sensor

Model number
(of set)
D5SN-S01 D5SN-S04 D5SN-S04-L D5SN-M05 D5SN-M10
Measurement range 1 mm 4 mm 5 mm 10 mm
Max. actuator travel
distance
Approx. 1.5 mm Approx. 5 mm Approx. 6 mm Approx. 12 mm
Resolution (See note 2.) 0.1 μm 0.4 μm 0.5 μm 1μm
Linearity (See note 3.) 0.3% FS max. 0.5% FS max. 0.5% FS max.
Repeat accuracy 0.5 μm max. 1.6 μm max. 10 μm max. 20 μm max.
Response time (not
including bounce time)
100 ms max. 200 ms max. 300 ms max.
Operating force
(See note 4.)
Approx. 0.7 N Approx. 0.25 N 5 N max.
Degree of protection (not
including the connector)
IP67 IP54 IP67
Mechanical durability 10,000,000 operations min.
Insulation/non-insulation
of mounting part
Insulated
Ambient operating
temperature
-10 to 60 °C (with no icing or condensation)
Ambient operating
humidity
25% to 95% (with no condensation)
Temperature influence
(See note 5.)
0.025% FS/°C 0.010% FS/°C 0.03% FS/°C
Weight Approx. 70 g (including cable connector) Approx. 230 g Approx. 300 g
Connection cable length 3-conductor shielded cable, 2 m

Note:
1. The above figures are for use with the standard actuator.
2. These figures are the smallest values that can be read when using OMRON’s K3NX Process Meter.
3. “FS” refers to the corresponding measurement range.
4. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or vertically, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
5. These figures are representative values that apply for the mid-point of the measurement range.

Amplifier

Model D5SN-A01
Supply voltage (allowable range) 12 to 24 VDC (10.8 to 26.4 VDC)
Current consumption 80 mA max.
Analog output
(See note 1.)
Voltage -5 to 5 V (load impedance: 10 kΩ min.)
Current 4 to 20 mA (load impedance: 300 Ω max.)
Enable output Output form NPN open collector
Output switching
current
100 mA max.
ON output residual
voltage
1.5 V max.
OFF collector
dielectric strength
26.4 VDC
OFF leakage current 0.1 mA max.
Degree of protection IP30
Ambient operating temperature -10 to 55 °C (with no icing or condensation)
Ambient operating humidity 25% to 85% (with no condensation)
Temperature influence (See note 2.) 0.010% FS/°C
Weight Approx. 200 g (including the cable)
Connection cable length 2-m-long, 5-conductor shielded cable

Note:
1. Depending on the offset adjustment and span adjustment, analog output may leave the specified range (−5 to 5 V or 4 to 20 mA) even for values within the specified measurement range.
2. These figures are representative values that apply for the mid-point of the measurement range.