Cam Positioner
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 8, 2013
| Model | 3F88L-160 | 3F88L-162 |
|---|---|---|
| Supply voltage | 100 to 240 VAC, 50/60 Hz | |
| Allowable supply voltage | 85 to 264 VAC | |
| Power consumption | 27 VA max. | |
| Inrush current | 40 A at 10 ms max. | |
| I/O power supply | 145 mA at 24 VDC | |
| Allowable I/O supply voltage | 20.4 to 26.4 VDC | |
| Insulation resistance | 20 MΩ min. between all external AC power supply terminals and the protective ground terminal (at 500 VDC) * | |
| Dielectric strength | 2,300 VAC at 50/60 Hz for 1 min between all external AC power supply terminals and the protective ground
terminal (leakage current: 10 mA max.) * |
|
| Noise immunity | IEC 61000-4-4: 2 kV power line | |
| Vibration resistance | Conforms to JIS C0911: 10 to 57 Hz with 0.075-mm single amplitude 80 min each in X, Y, and Z directions,
57 to 150 Hz at 9.8-m/s2 acceleration (sweeps: 8 min × 10 sweeps = 80 min total) |
|
| Shock resistance | Conforms to JIS C0912: 147 m/s2 three times each in X, Y, and Z directions | |
| Ambient operating temperature | 0 to 55°C | |
| Ambient operating humidity | 10% to 90% (with no condensation) | |
| Ambient operating atmosphere | No corrosive gases | |
| Ambient storage temperature | -20 to 75°C | |
| Terminals screw size | Power supply input: M3.5, control I/O: M3 | |
| Momentary power interruption
detection time |
Does not detect momentary power interruptions lasting less than 15 ms. | |
| Dimensions | 110 × 100 × 82.5 mm (W × H × D) | |
| Weight | 1 kg max. | |
| Structure | Mounted inside panel | |
| Mounting method | Screw mounting (two M4 screws) or DIN Track mounting | |
* Disconnect the functional ground terminal from the protective ground terminal before performing insulation resistance or dielectric strength tests.
| Model | 3F88L-160 | 3F88L-162 |
|---|---|---|
| No. of outputs | 16 | 32 |
| Output performance | Open-collector output, maximum switching capacity: 300 mA at 26.4 VDC (1.6 A max. per connector) | |
| No. of banks | 8 banks at 360 resolution, 4 banks at 720 resolution | |
| Display | 7-segment LED (current bank, speed, current angle) | |
| Response speed | 1,600 r/min at 360 resolution, 800 r/min at 720 resolution | |
| Detection cycle | 100 μs max. | |
| Reproducibility | 0.2° | |
| Memory backup | No. of non-volatile memory (EEPROM) writes: 100,000 times | |
| Control unit | 1/360 at 360 resolution, 1/720 at 720 resolution | |
| Origin compensation | 1 to 359 at 360 resolution, 1 to 719 at 720 resolution | |
| Backlash compensation | 1 to 179 at 360 resolution, 1 to 359 at 720 resolution | |
| Advance angle compensation | Advance angle compensation Range:1 to 359 at 360 resolution, 1 to 719 at 720 resolution
Speed input range: 1 to 1,600 at 360 resolution, 1 to 800 at 720 resolution Note: Only zero will be accepted for the angle advancement input when the speed input is zero. |
|
| Control inputs | START, TRIG, BANK 1 to 3, and RESET
Photocoupler input impedance: 4.7 kΩ |
|
| Control outputs | RUN, ERROR, and M·DET
Open-collector output, maximum switching capacity, 300 mA at 26.4 VDC |
|
| Speed detection accuracy | 5 r/min max. | |
last update: October 8, 2013