Smart Fiber Sensor
            
        
last update: August 16, 2021
| Type | Standard | Model for
 Sensor Communications Unit *1  | 
								|||
|---|---|---|---|---|---|
| NPN output | E3X-HD11 | E3X-HD6 | E3X-HD14 | E3X-HD0 | |
| PNP output | E3X-HD41 | E3X-HD8 | E3X-HD44 | ||
| Connecting method | Pre-wired | Wire-saving
 Connector *2  | 
									M8
 connector  | 
									Communications
 Unit connector  | 
								|
| Light source (wavelength) | Red, 4-element LED (625 nm) | ||||
| Power supply voltage | 12 to 24 VDC ±10%, ripple (P-P) 10% max. | Supplied from the connector
 through the Sensor Communications Unit  | 
								|||
| Power
 consump tion  | 
									Normal mode | 720 mW max.
 (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)  | 
								|||
| Eco ON | 530 mW max.
 (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC)  | 
								||||
| Eco LO | 640 mW max. (Current consumption: 26 mA max. at
 24 VDC, 53 mA max.at 12 VDC)  | 
									- | |||
| Control output | Load power supply voltage: 26.4 VDC max., open-
 collector output Load current: Groups of 1 to 3 Amplifier Units: 100mA max., Groups of 4 to 16 Amplifier Units: 20mA max. Residual voltage: At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max.  | 
									- | |||
| Protection circuits | Power supply reverse polarity protection, output
 short-circuit protection and output reverse polarity protection  | 
									Power supply reverse polarity
 protection and output short- circuit protection  | 
								|||
| Response
 time  | 
									Super-high-speed
 mode (SHS) *3  | 
									NPN outputs: Operate or reset: 50 μs
 PNP outputs: Operate or reset: 55 μs  | 
									- | ||
| High-speed Mode
 (HS)  | 
									Operate or reset: 250 μs (default setting) | ||||
| Standard Mode
 (STND)  | 
									Operate or reset: 1 ms | ||||
| Giga-power Mode
 (GIGA)  | 
									Operate or reset: 16 ms | ||||
| Maximum connectable Units | 16 units | with E3X-CRT: 16 units
 with E3X-ECT: 30 units  | 
								|||
| Mutual interference
 prevention  | 
									Possible for up to 10 units (optical communications sync) *3 | ||||
| Auto power control (APC) | Always ON | ||||
| Other functions | Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot),
 zero reset, resetting settings, and Eco mode  | 
								||||
| Ambient illumination
 (Receiver side)  | 
									Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
| Ambient temperature range | OOperating:
 Groups of 1 to 2 Amplifiers: -25 to 55°C, Groups of 3 to 10 Amplifiers: -25 to 50°C, Groups of 11 to 16 Amplifiers: -25 to 45°C Storage: -30 to 70°C (with no icing or condensation)  | 
									Operating:
 Groups of 1 to 2 Amplifiers: 0 to 55°C, Groups of 3 to 10 Amplifiers: 0 to 50°C, Groups of 11 to 16 Amplifiers: 0 to 45°C, Groups of 17 to 30 Amplifiers: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation)  | 
								|||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
| Vibration resistance
 (destruction)  | 
									10 to 55 Hz with a 1.5-mm double amplitude for
 2 hours each in X, Y, and Z directions  | 
									10 to 150 Hz with a 0.7-mm
 double amplitude for 80 minutes each in X, Y, and Z directions  | 
								|||
| Shock resistance
 (destruction)  | 
									500 m/s2 for 3 times each in X, Y, and Z
 directions  | 
									150 m/s2 for 3 times each in
 X, Y, and Z directions  | 
								|||
| Degree of protection | IEC 60529 IP50
 (with Protective Cover attached)  | 
									- | |||
| Weight
 (packed state/unit only)  | 
									Approx. 105 g/
 Approx. 65 g  | 
									Approx. 60 g/
 Approx. 20 g  | 
									Approx. 70 g/
 Approx. 25 g  | 
									Approx. 65 g/Approx. 25 g | |
| Materials | Case | Polycarbonate (PC) | Heat-resistant ABS
 (connector: PBT)  | 
								||
| Cover | Polycarbonate (PC) | ||||
| Cable | PVC | - | |||
| Accessories | Instruction Manual | ||||
| Sensing
 method  | 
									Sensing
 direction  | 
									Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard mode | High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Through-beam | Right-angle | M4 | E32-T11N 2M | 2,000 | 1,000 | 700 | 280 | 
| E32-LT11N 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
| Straight | E32-T11R 2M | 2,000 | 1,000 | 700 | 280 | ||
| E32-LT11 2M | 4,000 * | 4,000 * | 2,700 | 1,080 | |||
| E32-LT11R 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
| Reflective | Right-angle | M3 | E32-C31N 2M | 110 | 50 | 46 | 14 | 
| E32-C21N 2M | 290 | 130 | 90 | 39 | |||
| M4 | E32-D21N 2M | 840 | 350 | 240 | 100 | ||
| M6 | E32-C11N 2M | 780 | 350 | 320 | 100 | ||
| E32-LD11N 2M | 840 | 350 | 240 | 100 | |||
| Straight | M3 | E32-D21R 2M | 140 | 60 | 40 | 16 | |
| E32-C31 2M | 330 | 150 | 100 | 44 | |||
| E32-C31M 1M | |||||||
| M4 | E32-D211R 2M | 140 | 60 | 40 | 16 | ||
| M6 | E32-D11R 2M | 840 | 350 | 240 | 100 | ||
| E32-CC200 2M | 1,400 | 600 | 400 | 180 | |||
| E32-LD11 2M | 860 | 360 | 250 | 110 | |||
| E32-LD11R 2M | 840 | 350 | 240 | 100 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
									Size | Sensing
 direction  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Through-
 beam  | 
									1 dia. | Top-view | E32-T223R 2M | 450 | 250 | 150 | 60 | 
| 1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 | ||
| 3 dia. | E32-T12R 2M | 2,000 | 1,000 | 700 | 280 | ||
| Side-view | E32-T14LR 2M | 750 | 450 | 260 | 100 | ||
| Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 140 | 60 | 40 | 16 | 
| 1.5 dia. + 0.5 dia. | E32-D43M 1M | 28 | 12 | 8 | 4 | ||
| 3 dia. | E32-D22R 2M | 140 | 60 | 40 | 16 | ||
| E32-D221B 2M | 300 | 140 | 90 | 40 | |||
| E32-D32L 2M | 700 | 300 | 200 | 90 | |||
| 3 dia. + 0.8 dia. | E32-D33 2M | 70 | 30 | 20 | 8 | ||
| Sensing
 method  | 
									Sensing direction | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								|||
| Through-beam | Top-view | E32-T15XR 2M | 2,000 | 1,000 | 700 | 280 | 
| Side-view | E32-T15YR 2M | 750 | 450 | 260 | 100 | |
| Flat-view | E32-T15ZR 2M | |||||
| Reflective | Top-view | E32-D15XR 2M | 840 | 350 | 240 | 100 | 
| Side-view | E32-D15YR 2M | 200 | 100 | 52 | 24 | |
| Flat-view | E32-D15ZR 2M | |||||
| Sensing
 method  | 
									Sensing direction | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								|||
| Through-beam | Side-view | E32-T24R 2M | 170 | 100 | 50 | 20 | 
| E32-T24E 2M | 450 | 250 | 150 | 60 | ||
| Top-view | E32-T33 1M | 150 | 90 | 50 | 20 | |
| E32-T21-S1 2M | 510 | 300 | 170 | 68 | ||
| E32-TC200BR 2M | 2,000 | 1,000 | 700 | 280 | ||
| Reflective | Side-view | E32-D24R 2M | 70 | 30 | 20 | 8 | 
| E32-D24-S2 2M | 120 | 53 | 45 | 14 | ||
| Top-view | E32-D43M 1M | 28 | 12 | 8 | 4 | |
| E32-D331 2M | 14 | 6 | 4 | 2 | ||
| E32-D33 2M | 70 | 30 | 20 | 8 | ||
| E32-D32-S1 0.5M | 63 | 24 | 18 | 7 | ||
| E32-D31-S1 0.5M | ||||||
| E32-DC200F4R 2M | 140 | 60 | 40 | 16 | ||
| E32-D22-S1 2M | 250 | 110 | 72 | 30 | ||
| E32-D21-S3 2M | ||||||
| E32-DC200BR 2M | 840 | 350 | 240 | 100 | ||
| E32-D25-S3 2M | 250 | 110 | 72 | 30 | ||
| Type | Spot
 diameter  | 
									Center
 distance (mm)  | 
									Models | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
									Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Variable
 spot  | 
									0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M+E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
| 0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M+E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
| Parallel
 light  | 
									4 dia. | 0 to 20 | E32-C31 2M+E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
| E32-C31N 2M+E39-F3C | |||||||
| Integrated
 lens  | 
									0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
| 6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | ||||
| Small-
 spot  | 
									0.1 dia. | 7 | E32-C41 1M+E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
| 0.5 dia. | E32-C31 2M+E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
| E32-C31N 2M+E39-F3A-5 | |||||||
| 0.2 dia. | 17 | E32-C41 1M+E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
| 0.5 dia. | E32-C31 2M+E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
| E32-C31N 2M+E39-F3B | |||||||
| 3 dia. | 50 | E32-CC200 2M+E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
| E32-C11N 2M+E39-F18 | |||||||
| Type | Sensing
 direction  | 
									Aperture
 angle  | 
									Models | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
									Standard
 mode  | 
									High-
 speed mode  | 
									Super-
 high- speed mode  | 
								||||
| Through-beam
 models with integrated lens  | 
									Right-angle | 15° | E32-LT11N 2M | 4,000 *2 | 3,500 | 2,300 | 920 | 
| Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
| 15° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 2,700 | 1,080 | ||
| E32-LT11R 2M | 4,000 *2 | 3,500 | 2,300 | 920 | |||
| Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
| Through-beam
 models with lenses  | 
									Right-angle | 12° | E32-T11N 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | 
| 6° | E32-T11N 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
| Top-view | 12° | E32-T11R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | |
| 6° | E32-T11R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
| Side-view | 60° | E32-T11R 2M+E39-F2 | 1,450 | 800 | 500 | 200 | |
| Top-view | 12° | E32-T11 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
| 6° | E32-T11 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Side-view | 60° | E32-T11 2M+E39-F2 | 2,300 | 1,320 | 860 | 320 | |
| Top-view | 12° | E32-T51R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 3,900 | 1,500 | |
| 6° | E32-T51R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Side-view | 60° | E32-T51R 2M+E39-F2 | 1,400 | 720 | 500 | 200 | |
| Top-view | 12° | E32-T81R-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 2,700 | 1,000 | |
| 6° | E32-T81R-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
| Side-view | 60° | E32-T81R-S 2M+E39-F2 | 1,000 | 550 | 360 | 140 | |
| Top-view | 12° | E32-T61-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
| 6° | E32-T61-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
| Side-view | 60° | E32-T61-S 2M+E39-F2 | 1,680 | 900 | 600 | 240 | |
| Top-view | 12° | E32-T51 2M+E39-F1-33 | 4,000 *2 | 4,000 *2 | 2,300 | 1,400 | |
| 6° | E32-T51 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Reflective
 models with integrated lens  | 
									Top-view | 4° | E32-D16 2M | 40 to
 2,800  | 
									40 to
 1,400  | 
									40 to 900 | 40 to 480 | 
            *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
        
| Sensing
 method  | 
									Sensing
 direction  | 
									Aperture
 angle  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Through-beam | Side-view | 1.5° | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 | 
| E32-A03-1 2M | |||||||
| 3.4° | E32-A04 2M | 1,280 | 680 | 450 | 200 | ||
| 4° | E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | ||
| E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 | |||
| E32-T22S 2M | 4,000 * | 3,800 | 2,500 | 1,000 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
									Sensing
 direction  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard mode | High-speed
 mode  | 
									Super-high-speed
 mode  | 
								|||
| Limited-
 reflective  | 
									Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
| E32-L24S 2M | 0 to 4 | |||||
| Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
| Sensing
 method  | 
									Feature | Size | Models | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Retro-
 reflective  | 
									Film detection | M3 | E32-C31 2M
 +E39-F3R +E39-RP37  | 
									250 | 200 | --- | |
| Square | --- | E32-R16 5M | 150 to 1,500 | ||||
| Threaded | M6 | E32-R21 2M | 10 to 250 | ||||
| Hex-shaped | E32-LR11NP 2M
 +E39-RP1  | 
									1,350 | 1,200 | 1,000 | 550 | ||
| Sensing
 method  | 
									Feature | Sensing
 direction  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
									Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Limited-
 reflective  | 
									Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
| Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
| Glass substrate
 alignment, 70°C  | 
									E32-A08 2M | 10 to 20 | --- | ||||
| Standard/long-distance | E32-A12 2M | 12 to 30 | --- | ||||
| Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
| Glass substrate
 mapping, 70°C  | 
									Top-view | E32-A09 2M | 15 to 38 | --- | |||
| Sensing
 method  | 
									Type | Sensing
 direction  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Through-
 beam  | 
									Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 | 
| Chemical/
 oil-resistant  | 
									Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
| E32-T11F 2M | 4,000 *1 | 4,000 *1 | 2,600 | 1,000 | |||
| Side-view | E32-T14F 2M | 1,400 | 800 | 500 | 200 | ||
| Chemical/
 oil-resistant at 150°C  | 
									Top-view | E32-T51F 2M | 4,000 *1 | 2,800 | 1,800 | 700 | |
| Reflective | Semiconductors:
 Cleaning, developing, and etching; 60°C  | 
									Top-view | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)  | 
								|||
| Semiconductors:
 Resist stripping; 85°C  | 
									E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
								|||||
| Chemical/
 oil-resistant  | 
									E32-D12F 2M | --- *2 | 190 | 130 | 60 | ||
| Chemical-
 resistant cable  | 
									E32-D11U 2M | 840 | 350 | 240 | 100 | ||
            *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
        
| Sensing
 method  | 
									Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard mode | High-speed
 mode  | 
									Super-high-speed
 mode  | 
								|||
| Through-beam | 1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 | 
| M3 | E32-T21 2M | |||||
| M4 | E32-T11 2M | 2,500 | 1,350 | 900 | 360 | |
| Square | E32-T25XB 2M | 500 | 300 | 170 | 70 | |
| Reflective | 1.5 dia. | E32-D22B 2M | 140 | 60 | 40 | 16 | 
| M3 | E32-D21 2M | |||||
| 3 dia. | E32-D221B 2M | 300 | 140 | 90 | 40 | |
| M4 | E32-D21B 2M | |||||
| M6 | E32-D11 2M | 840 | 350 | 240 | 100 | |
| Square | E32-D25XB 2M | 240 | 100 | 60 | 30 | |
| Sensing
 method  | 
									Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard mode | High-speed
 mode  | 
									Super-high-
 speed mode  | 
								|||
| Through-beam | 100°C | E32-T51R 2M | 1,600 | 800 | 560 | 225 | 
| 150°C | E32-T51 2M | 2,800 | 1,500 | 1,000 | 400 | |
| 200°C | E32-T81R-S 2M | 1,000 | 550 | 360 | 140 | |
| 350°C | E32-T61-S 2M | 1,680 | 900 | 600 | 240 | |
| Reflective | 100°C | E32-D51R 2M | 670 | 280 | 190 | 80 | 
| 150°C | E32-D51 2M | 1,120 | 450 | 320 | 144 | |
| 200°C | E32-D81R-S 2M | 420 | 180 | 120 | 54 | |
| 300°C | E32-A08H2 2M | 10 to 20 | --- | |||
| E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
| 350°C | E32-D611-S 2M | 420 | 180 | 120 | 54 | |
| E32-D61-S 2M | ||||||
| 400°C | E32-D73-S 2M | 280 | 120 | 80 | 36 | |
| Sensing
 method  | 
									Type | Sensing width | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Through-beam | Area | 11 mm | E32-T16PR 2M | 3,100 | 1,700 | 1,120 | 440 | 
| E32-T16JR 2M | 2,750 | 1,500 | 960 | 380 | |||
| 30 mm | E32-T16WR 2M | 4,000 | 2,600 | 1,700 | 680 | ||
| Reflective | Array | 11 mm | E32-D36P1 2M | 700 | 300 | 200 | 90 | 
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
									Tube
 diameter  | 
									Feature | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Tube-
 mounting  | 
									3.2, 6.4, or
 9.5 dia  | 
									Stable
 residual quantity detection  | 
									E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2,
 6.4, or 9.5 mm, Recommended wall thickness: 1 mm  | 
								|||
| 8 to 10 dia | Mounting at
 multiple levels  | 
									E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8
 to 10 mm, Recommended wall thickness: 1 mm  | 
								||||
| No
 restrictions  | 
									Large tubes | E32-D36T 5M | Applicable tube: Transparent tube
 (no restrictions on diameter)  | 
								||||
| Liquid contact
 (heat-resistant up to 200°C)  | 
									--- | --- | E32-D82F1 4M | Liquid-contact type | |||
| Sensing
 method  | 
									Heat-resistant
 temperature  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								|||
| Through-beam | 120 °C | E32-T51V 1M | 720 | 400 | 260 | 100 | 
| E32-T51V 1M+E39-F1V | 2,000 * | 2,000 * | 1,360 | 520 | ||
| 200 °C | E32-T84SV 1M | 1,760 | 950 | 640 | 260 | |
* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
| Sensing
 method  | 
									Application | Operating
 temperature  | 
									Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga mode | Standard
 mode  | 
									High-speed
 mode  | 
									Super-high-
 speed mode  | 
								||||
| Limited-
 reflective  | 
									Glass presence
 detection  | 
									70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
| E32-A08 2M | 10 to 20 | --- | |||||
| Glass substrate
 alignment  | 
									300°C | E32-A08H2 3M | |||||
| 70°C | E32-A12 2M | 12 to 30 | --- | ||||
| Glass substrate
 mapping  | 
									E32-A09 2M | 15 to 38 | --- | ||||
| 300°C | E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
| Wet processes:
 Cleaning, Resist developing and etching  | 
									60°C | E32-L11FP 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)  | 
								||||
| Wet process:
 Resist stripping  | 
									85°C | E32-L11FS 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
								||||
| Through-
 beam  | 
									Wafer mapping | 70°C | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 | 
| E32-A03-1 2M | |||||||
| E32-A04 2M | 1,280 | 680 | 450 | 200 | |||
| E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | |||
| E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
last update: August 16, 2021