Smart Sensor 2D Measurement Type
last update: June 1, 2023
Model | ZS-HLDC11-N | ZS-HLDC41-N | ||
---|---|---|---|---|
No. of samples to average | 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 | |||
Number of mounted Sensors | 1 per Sensor Controller | |||
External
interface |
Connection method | Serial I/O: connector, Other: pre-wired (Standard cable length: 2 m) | ||
Serial
I/O |
USB 2.0 | 1 port, Full Speed (12 Mbps max.), MINI-B | ||
RS-232C | 1 port, 115,200 bps max. | |||
Output | Judgment
output |
HIGH/PASS/LOW 3 outputs
NPN open collector, 30 VDC, 50 mA max., residual voltage 1.2 V max. |
HIGH/PASS/LOW: 3 outputs
PNP open collector, 50 mA max., residual voltage 1.2 V max. |
|
Linear output | Selectable from 2 types of output, voltage or current (selected by slide switch on
bottom). • Voltage output: -10 to 10 V, output impedance: 40 • Current output: 4 to 20 mA, maximum load resistance: 300 |
|||
Inputs | Laser OFF,
ZERO reset timing, RESET |
ON: Short-circuited with 0 V terminal
or 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) |
ON: Short-circuited to supply voltage
or within 1.5 V of supply voltage. OFF: Open (leakage current: 0.1 mA max.) |
|
Functions | Display: Measured value, threshold value, voltage/current, received light amount,
and resolution/terminal block output Sensing: Mode, gain, measurement object, head installation Measurement point: Average, peak, bottom, thickness, step, and calculations Filter: Smooth, average, and differentiation Outputs: Scaling, various hold values, and zero reset I/O settings: Linear (focus/correction), judgments (hysteresis and timer), non- measurement, and bank (switching and clear) System: Save, initialization, measurement information display, communications settings, key lock, language, and data load Task: Single task or multitask (up to 4) |
|||
Status indicators | HIGH (orange), PASS (green), LOW (orange), LDON (green), ZERO (orange), and
ENABLE (green) |
|||
Segment display | Main digital | 8-segment red LED, 6 digits | ||
Sub-digital | 8-segment green LEDs, 6 digits | |||
LCD | 16 digits x 2 rows, Color of characters: green, Resolution per character: 5 x 8 pixel
matrix |
|||
Setting | Setting keys | Direction keys (UP, DOWN, LEFT, and RIGHT), SET key, ESC key, MENU key, and
function keys (1 to 4) |
||
Slide switch | Threshold switch (2 states: High/Low), mode switch (3 states: FUN, TEACH, and
RUN) |
|||
Power supply voltage | 21.6 V to 26.4 VDC (including ripple) | |||
Current consumption | 0.5 A max. (when Sensor Head is connected) | |||
Ambient temperature | Operating: 0 to 50°C, Storage: -15 to +60°C (with no icing or condensation) | |||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
Degree of protection | IP20 (IEC60529) | |||
Materials | Case: Polycarbonate (PC) | |||
Cable length | 2 m | |||
Weight | Approx. 280 g (excluding packing materials and accessories) | |||
Accessories | Ferrite core (1), instruction sheet |
Model | ZS-HLDS2VT | ZS-HLDS5T | ||
---|---|---|---|---|
Optical system | Regular reflection | Diffuse reflection | Regular reflection | |
Measuring center
distance |
25 mm | 50 mm | 44 mm | |
Measuring range | ±2 mm | ±5 mm | ±4 mm | |
Light source | Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) | |||
Beam shape | Line beam | |||
Beam diameter *1 | 2.2mm × 45 μm | 1.0mm × 30 μm | ||
Linearity *2 | ±0.2% F.S. | ±0.1% F.S. | ||
Resolution *3 | 0.6 μm
(No. of samples to average: 128) |
0.25 μm
(No. of samples to average: 512) |
||
Temperature
characteristic *4 |
±0.1% F.S./°C | 0.01% F.S./°C | ||
Sampling cycle | 110 μs (High-speed Mode), 500 μs (Standard Mode), 2.2 ms (High-precision Mode),
4.4 ms (High-sensitivity Mode) |
|||
LED
Indicators |
NEAR
indicator |
Lights near the measuring center distance, and closer than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
||
FAR
indicator |
Lights near the measuring center distance, and farther than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
|||
Operating ambient
illumination |
Illumination on received light surface: 3000 lx or less (incandescent light) | |||
Ambient
temperature |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | |||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
Degree of
protection *5 |
IP67 | Cable length 0.5 m: IP66,
cable length 2 m: IP67 |
||
Materials | Case: Aluminum die-cast, Front cover: Glass | |||
Cable length | 2 m | 0.5 m, 2 m | ||
Weight | Approx. 350 g | Approx. 600 g | ||
Accessories | ZS-HLDS2VT:
Laser labels (1 each for JIS/EN), ferrite cores (2), insure locks (2), instruction sheet ZS-HLDS5T/-HLDS10/-HLDS60/-HLDS150: Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (4), insure locks (2), instruction sheet |
Model | ZS-HLDS10 | ZS-HLDS60 | ZS-HLDS150 | ||
---|---|---|---|---|---|
Optical system | Diffuse
reflection |
Regular
reflection |
Diffuse reflection | Diffuse reflection | |
Measuring center
distance |
100 mm | 94 mm | 600 mm | 1,500 mm | |
Measuring range | ±20 mm | ±16 mm | ±350 mm | ±500 mm | |
Light source | Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) | ||||
Beam shape | Line beam | ||||
Beam diameter *1 | 3.5mm × 60 μm | 16 × 0.3 mm
(at 500 mm) |
40 × 1.5 mm
(at 1,500 mm) |
||
Linearity *2 | ±0.1% F.S. | ±0.07% F.S.
(250 to 750 mm) ±0.1% F.S. (750 to 950 mm) |
±0.2% F.S. | ||
Resolution *3 | 1 μm
(No. of samples to average: 64) |
μm (No. of samples to
average: 64 at 250 mm), 40 μm (No. of samples to average: 64 at 600 mm) |
500 μm
(No. of samples to average: 64) |
||
Temperature
characteristic *4 |
0.01% F.S./°C | ||||
Sampling cycle | 110 μs (High-speed Mode), 500 μs (Standard Mode), 2.2 ms (High-precision Mode),
4.4 ms (High-sensitivity Mode) |
||||
LED
Indicators |
NEAR
indicator |
Lights near the measuring center distance, and closer than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
|||
FAR
indicator |
Lights near the measuring center distance, and farther than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
||||
Operating ambient
illumination |
Illumination on received light surface:
3000 lx or less (incandescent light) |
Illumination on received
light surface: 1000 lx or less (incandescent light) |
Illumination on received
light surface: 500 lx or less (incandescent light) |
||
Ambient
temperature |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | ||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | ||||
Degree of
protection *5 |
Cable length 0.5 m: IP66,
cable length 2 m: IP67 |
IP66 *6 | |||
Materials | Case: Aluminum die-cast, Front cover: Glass | ||||
Cable length | 0.5 m, 2 m | ||||
Weight | Approx. 600 g | Approx. 800 g | |||
Accessories | ZS-HLDS2VT:
Laser labels (1 each for JIS/EN), ferrite cores (2), insure locks (2), instruction sheet ZS-HLDS5T/-HLDS10/-HLDS60/-HLDS150: Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (4), insure locks (2), instruction sheet |
*1 Defined as 1/e2 (13.5%) of the center optical intensity at the actual measuring center distance (effective value).
The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the
main beam.
*2. This is the error in the measured value with respect to an ideal straight line.
Linearity may change according to the workpiece.
The following options are available.
Model | Diffuse reflection | Mirror reflection |
---|---|---|
ZS-HLDS2VT | --- | Glass |
ZS-HLDS5T | White alumina ceramic | Glass |
ZS-HLDS10 | White alumina ceramic | |
ZS-HLDS60/HLDS150 | White alumina ceramic | --- |
*3. This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance
in high-precision mode when the number of samples to average is set to within the graph.
The maximum resolution at 250 mm is also shown for the ZS-HLDS60. The following options are available.
Model | Diffuse reflection | Mirror reflection |
---|---|---|
ZS-HLDS2VT | --- | Glass |
ZS-HLDS5T | White alumina ceramic | Glass |
ZS-HLDS10 | White alumina ceramic | |
ZS-HLDS60/HLDS150 | White alumina ceramic | --- |
*4 This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig.
(typical example)
*5 Protection structure of connector area is IP40.
*6 Ask your OMRON representative about Sensor Heads with IP67 protection.
Model | ZS-LD20T | ZS-LD20ST | ZS-LD40T | ZS-LD10GT | ZS-LD15GT | ||||
---|---|---|---|---|---|---|---|---|---|
Optical system | Regular
reflection |
Diffuse
reflection |
Regular
reflection |
Diffuse
reflection |
Diffuse
reflection |
Diffuse
reflection |
Regular reflection | ||
Measuring center
distance |
20 mm | 6.3 mm | 20 mm | 6.3 mm | 40 mm | 30 mm | 10 mm | 15 mm | |
Measuring range | ±1 mm | ±1 mm | ±1 mm | ±1 mm | ±2.5 mm | ±2 mm | ±0.5 mm | ±0.75 mm | |
Light source | Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) | ||||||||
Beam shape | Line beam | Spot beam | Line beam | ||||||
Beam diameter *1 | 900 × 25 μm | 25 μm dia. | 2,000 × 35 μm | Approx. 25 × 900 μm | |||||
Linearity *2 | ±0.1% F.S. | ||||||||
Resolution *3 | 0.25 μm | 0.25 μm | 0.4 μm | 0.25 μm | 0.25 μm | ||||
Temperature
characteristic *4 |
0.04% F.S./°C | 0.04% F.S./°C | 0.02% F.S./°C | 0.04% F.S./°C | |||||
Sampling cycle | 110 μs (High-speed Mode), 500 μs (Standard Mode), 2.2 ms (High-precision Mode),
4.4 ms (High-sensitivity Mode) |
||||||||
LED
Indicators |
NEAR
indicator |
Lights near the measuring center distance, and closer than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
|||||||
FAR
indicator |
Lights near the measuring center distance, and farther than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
||||||||
Operating ambient
illumination |
Illumination on received light surface: 3000 lx or less (incandescent light) | ||||||||
Ambient temperature | Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | ||||||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | ||||||||
Degree of protection
*5 |
Cable length 0.5 m: IP66, cable length 2 m: IP67 | IP40 | |||||||
Materials | Case: Aluminum die-cast, Front cover: Glass | ||||||||
Cable length | 0.5 m, 2 m | ||||||||
Weight | Approx. 350 g | ||||||||
Accessories | Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2),
insure locks (2), instruction sheet |
Laser safety labels
(1 each for JIS/EN), ferrite cores (2), insure locks (2) |
*1 Defined as 1/e2 (13.5%) of the center optical intensity at the actual measuring center distance (effective value).
The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam.
*2 This is the error in the measured value with respect to an ideal straight line.
The standard workpiece is white aluminum ceramics and glass in the regular reflection mode.
Linearity may change according to the workpiece.
*3 This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode.
The standard workpiece is white aluminum ceramics and glass in the regular reflection mode.
*4 This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig. (typical example)
*5 Protection structure of connector area is IP40.
Model | ZS-LD50 | ZS-LD50S | ZS-LD80 | ||||
---|---|---|---|---|---|---|---|
Optical system | Diffuse
reflection |
Regular
reflection |
Diffuse
reflection |
Regular
reflection |
Diffuse
reflection |
Regular
reflection |
|
Measuring center
distance |
50 mm | 47 mm | 50 mm | 47 mm | 80 mm | 78 mm | |
Measuring range | ±5 mm | ±4 mm | ±5 mm | ±4 mm | ±15 mm | ±14 mm | |
Light source | Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) | ||||||
Beam shape | Line beam | Spot beam | Line beam | ||||
Beam diameter *1 | 900 × 60 μm | 50 μm dia. | 900 × 60 μm | ||||
Linearity *2 | ±0.1% FS | ||||||
Resolution *3 | 0.8 μm | 0.8 μm | 2 μm | ||||
Temperature
characteristic *4 |
0.02% FS/°C | 0.02% FS/°C | 0.01% FS/°C | ||||
Sampling cycle | 110 μs (High-speed Mode), 500 μs (Standard Mode), 2.2 ms (High-precision Mode),
4.4 ms (High-sensitivity Mode) |
||||||
LED
Indicators |
NEAR
indicator |
Lights near the measuring center distance, and closer than the measuring center distance
inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
|||||
FAR
indicator |
Lights near the measuring center distance, and farther than the measuring center distance
inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
||||||
Operating ambient
illumination |
Illumination on received light surface: 3000 lx or less (incandescent light) | ||||||
Ambient temperature | Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | ||||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | ||||||
Degree of
protection *5 |
Cable length 0.5 m: IP66, cable length 2 m: IP67 | ||||||
Materials | Case: Aluminum die-cast, Front cover: Glass | ||||||
Cable length | 0.5 m, 2 m | ||||||
Weight | Approx. 350g | ||||||
Accessories | Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure locks (2),
instruction sheet |
Model | ZS-LD130 | ZS-LD200 | ZS-LD350S | |||
---|---|---|---|---|---|---|
Optical system | Diffuse reflection | Regular reflection | Diffuse reflection | Regular reflection | Diffuse reflection | |
Measuring center
distance |
130 mm | 130 mm | 200 mm | 200 mm | 350 mm | |
Measuring range | ±15 mm | ±12 mm | ±50 mm | ±48 mm | ±135 mm | |
Light source | Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) | |||||
Beam shape | Line beam | Line beam | Spot beam | |||
Beam diameter *1 | 600 × 70 μm | 900 × 100 μm | 240 μm dia. | |||
Linearity *2 | ±0.1% FS | ±0.25% FS | ±0.1% FS | ±0.25% FS | ±0.1% FS | |
Resolution *3 | 3 μm | 5 μm | 20 μm | |||
Temperature
characteristic *4 |
0.02% FS/°C | 0.02% FS/°C | 0.04% FS/°C | |||
Sampling cycle | 110 μs (High-speed Mode), 500 μs (Standard Mode), 2.2 ms (High-precision Mode),
4.4 ms (High-sensitivity Mode) |
|||||
LED
Indicators |
NEAR
indicator |
Lights near the measuring center distance, and closer than the measuring center distance
inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
||||
FAR
indicator |
Lights near the measuring center distance, and farther than the measuring center distance
inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. |
|||||
Operating ambient
illumination |
Illumination on received light surface:
2000 lx or less (incandescent light) |
Illumination on received light surface:
3000 lx or less (incandescent light) |
||||
Ambient temperature | Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | |||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||||
Degree of
protection *5 |
Cable length 0.5 m: IP66, cable length 2 m: IP67 | |||||
Materials | Case: Aluminum die-cast, Front cover: Glass | |||||
Cable length | 0.5 m, 2 m | |||||
Weight | Approx. 350g | |||||
Accessories | Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure locks (2),
instruction sheet |
*1 Defined as 1/e2 (13.5%) of the center optical intensity at the actual measuring center distance (effective value).
The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam.
*2 This is the error in the measured value with respect to an ideal straight line.
The standard workpiece is white aluminum ceramics and glass in the ZS-LD50/LD50S regular reflection mode.
Linearity may change according to the workpiece.
*3 This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode.
The standard workpiece is white aluminum ceramics and glass in the ZS-LD50/LD50S regular reflection mode.
*4 This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig.
*5 Protection structure of connector area is IP40.
last update: June 1, 2023