Small Limit Switch
            
        
last update: December 27, 2013
| Certification body | Standard | File No. | 
|---|---|---|
| CCC | GB14048.5 | Consult your OMRON representative for details. | 
| UL * | UL508, CSA C22.2 No. 14 | |
| TÜV | IEC60947-5-1 | 
* Certification equivalent to CSA C22.2 No. 14 has been obtained from UL.
| Rated voltage
 (V)  | 
									Non-inductive load (A) | Inductive load (A) | ||||||
|---|---|---|---|---|---|---|---|---|
| Resistive load | Lamp load | Inductive load | Motor load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125 VAC
 250 VAC  | 
									5
 5  | 
									1.5
 1  | 
									0.7
 0.5  | 
									3
 3  | 
									2
 1.5  | 
									1
 0.8  | 
								||
| 12 VDC
 24 VDC  | 
									5
 5  | 
									3
 3  | 
									4
 4  | 
									3
 3  | 
								||||
| 125 VDC
 250 VDC  | 
									0.4
 0.4  | 
									0.2
 0.2  | 
									---
 ---  | 
									---
 ---  | 
									---
 ---  | 
								|||
| Inrush current | NC | 24 A max. | 
|---|---|---|
| NO | 12 A max. | 
| Category and rating | 
|---|
| AC-12: 250 VAC at 5 A, resistive load
 DC-12: 125 VDC at 0.4 A, resistive load  | 
								
| Ratings | 
|---|
| 5 A, 250 VAC
 0.4 A, 125 VDC  | 
								
| Degree of protection | IP65 | |
|---|---|---|
| Durability
 (See note 3.)  | 
									Mechanical | 10,000,000 operations min. | 
| Electrical | 300,000 operations min. (5 A at 250 VAC, resistive load) | |
| Operating speed | 5 mm to 0.5 m/s | |
| Operating frequency | Mechanical | 120 operations/min | 
| Electrical | 30 operations/min | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |
| Contact resistance | 25 mΩ max. (initial value) | |
| Dielectric strength | Between terminals of the
 same polarity  | 
									1,000 VAC, 50/60 Hz for 1 min | 
| Between currentcarrying
 metal parts and ground  | 
									1,500 VAC, 50/60 Hz for 1 min | |
| Rated insulation voltage (Ui) | 250 V | |
| Pollution degree (application environment) | 3 (EN 60947-5-1) | |
| Short-circuit protection device | 10-A fuse, gG or gI (IEC 269) | |
| Conditional short-circuit current | 100 A (EN 60947-5-1) | |
| Rated open thermal current (lth) | 5 A (EN 60947-5-1) | |
| Electric shock protection class | Class I | |
| Rated frequency | 50/60 Hz | |
| Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude (See note 4.) | 
| Shock resistance | Destruction | 1,000 m/s2 (free position) min. | 
| Malfunction | 300 m/s2 (operation limit position) min. (See note 4.) | |
| Ambient operating temperature range | -20°C to 60°C (with no icing) | |
| Ambient operating humidity range | 90% max. | |
| Weight | Approx. 130 to 190 g | |
| Model | D4V-8104Z | D4V-8107Z | D4V-8108Z | D4V-8111Z | |
|---|---|---|---|---|---|
| Operating characteristics | |||||
| Operating force | OF max. | 5.88 N | 5.88 N | 7.84 N | 9.8 N | 
| Release force | RF min. | 0.49 N | 0.69 N | 0.49 N | 2.94 N | 
| Pretravel | PT max. | 20° | 20° | 20° | 1.5 mm | 
| Overtravel | OT min. | 75° | 75° | 75° | 4 mm | 
| Movement differential | MD max. | 10° | 10° | 10° | 1.2 mm | 
| Total travel | TT min. | 95° | 95° | 95° | 5.5 mm | 
| Operating position | OP | --- | --- | --- | 26±0.8 mm | 
| Model | D4V-8112Z | D4V-8122Z | D4V-8166Z | D4V-8169Z | |
|---|---|---|---|---|---|
| Operating characteristics | |||||
| Operating force | OF max. | 9.8 N | 9.8 N | 0.88 N | 0.88 N | 
| Release force | RF min. | 2.94 N | 2.94 N | --- | --- | 
| Pretravel | PT max. | 1.5 mm | 1.5 mm | 30 mm | 30 mm | 
| Overtravel | OT min. | 4 mm | 4 mm | --- | --- | 
| Movement differential | MD max. | 1.2 mm | 1.2 mm | --- | --- | 
| Total travel | TT min. | 5.5 mm | 5.5 mm | --- | --- | 
| Operating position | OP | 37±0.8 mm | 37±0.8 mm | --- | --- | 
last update: December 27, 2013