Smartlice
last update: February 13, 2014
Common SmartSlice Specifications
|
|
---|---|
Unit power supply voltage | 24 VDC (20.4 to 26.4 VDC) |
I/O power supply voltage | 24 VDC (20.4 to 26.4 VDC) |
I/O connection | Screwless push-in technology |
Noise immunity | Conforms to IEC61000-4-4, 2.0 kV (power supply line) |
Vibration resistance | 10 to 60 Hz: 0.7 mm double amplitude 60 to 150 Hz: 50 m/s2 |
Shock resistance | 150 m/s2, 3 times in each direction |
Dielectric strength | 500 VAC (between isolated circuits) |
Insulation resistance | 20 MΩ min. (between isolated circuits) |
Ambient operating temperature | -10 to 55°C (with no icing or condensation) |
Ambient operating humidity | 25% to 85% |
Operating environment | No corrosive gases |
Ambient storage temperature | -25 to 65°C (with no icing or condensation) |
Mounting | 35 mm DIN rail |
Model name
|
GRT1-ECT
|
---|---|
Network Specification | EtherCAT for Trajexia and Sysmac (NJ) |
Network connector | 2 x RJ45 |
Network interface power supply | External 24 VDC
(+10% - 15%) |
Number of I/O points | 1,024 inputs and outputs max. (128 bytes total) |
Number of connectable Units | 64 SmartSlice I/O Units max. |
I/O power supply | 24 VDC, 4 A max. |
Status flags | 1 word for Communications Unit status flags |
Parameter backup and restore | up to 2 KB of data per I/O Unit. |
last update: February 13, 2014