Liquid Level Sensor
last update: June 1, 2020
| Item | E2K-L13MC[] | E2K-L26MC[] | ||
|---|---|---|---|---|
| Applicable
pipes |
Materials | Non-metal | ||
| Size | Diameter | 8 to 11 mm | 12 to 26 mm | |
| Thickness | 1 mm max. | 1.5 mm max. | ||
| Detectable object | Liquid * | |||
| Repeat accuracy | ±0.2 mm max. | |||
| Differential travel
(Reference value, varies with pipe size and liquid.) |
0.6 to 5 mm | 0.3 to 3 mm | ||
| Power supply voltage
(operating voltage range) |
12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max. | |||
| Current consumption | 12 mA max. | |||
| Control output | Load current | 100 mA max. | ||
| Residual
voltage |
1 V max. (Load current: 100 mA, Cable length: 2 m) | |||
| Sensing liquid position | Indented mark position (For details, refer to Datasheet) | |||
| Indicators | Detection indicator (orange) | |||
| Ambient temperature range | Operating: 0 to 55°C (with no icing or condensation),
Storage: -10 to 65°C (with no icing or condensation) |
|||
| Ambient humidity range | Operating/Storage: 25% to 85% (with no condensation) | |||
| Temperature influence | ±4 mm of detection level at 23°C in the temperature range of 0 to 55°C
(with pure water or 20% saline solution) (±6 mm for E2K-L13MC[] with pure water and a pipe diameter of 8 mm) |
|||
| Voltage influence | ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range | |||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y,
and Z directions |
|||
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection | IP66 (IEC) | |||
| Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
| Weight (packed state) | Approx. 70 g | |||
| Materials | Case, Cover | Heat-resistant ABS | ||
| Cable clamp | NBR | |||
| Accessories | Two bands, Four slip-proof tubes, One driver for sensitivity adjustment,
Instruction manual |
|||