Incremental 25-mm-dia. Rotary Encoder
            
        
last update: February 18, 2013
| Model | E6A2-CWZ3E | E6A2-CWZ3C | E6A2-CWZ5C | |
|---|---|---|---|---|
| Power supply voltage | 5 VDC -5% to 12 V +10%, ripple (p-p): 5% max.  | 
                12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max.  | 
              ||
| Current consumption *1 | 50 mA max. | 30 mA max. | ||
| 
                  Resolution (pulses/rotation)  | 
                100, 200, 360, 500 | |||
| Output phases | Phases A, B, and Z | |||
| Output configuration | Voltage output | NPN open-collector output | ||
| Output capacity | Output resistance: 2 kΩ Output current: 20 mA max. Residual voltage: 0.4 V max. (Output current: 20 mA max.)  | 
                Applied voltage: 30 VDC max. Sink current: 30 mA max. Residual voltage: 0.4 V max. (at sink current of 30 mA)  | 
              ||
| 
                  Maximum response frequency *2  | 
                30 kHz | |||
| 
                  Phase difference between outputs  | 
                Phase difference between phases A and B: 90°±45° | |||
| Output duty factor | --- | |||
| 
                  Rise and fall times of output  | 
                1.0 μs max. (Cable length: 500 mm, Sink current: 10 mA)  | 
                1.0 μs max. (Cable length: 500 mm, Control output voltage: 5 V, Load resistance: 1 kΩ)  | 
              ||
| Starting torque | 1 mNm max. | |||
| Moment of inertia | 1 × 10-7 kgm2 max. | |||
| Shaft loading | Radial | 10 N | ||
| Thrust | 50 N | |||
| 
                  Maximum permissible speed  | 
                5,000 r/min | |||
| 
                  Ambient temperature range  | 
                Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing) | |||
| Ambient humidity range | Operating/storage: 35% to 85% (with no condensation) | |||
| Insulation resistance | 20 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection *3 | IEC 60529 IP50 | |||
| Connection method | Pre-wired Models (Standard cable length: 500 mm) | |||
| Material | Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron | |||
| Weight (packed state) | Approx. 35 g | |||
| Accessories | Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual | |||
| Model | E6A2-CW3E | E6A2-CW3C | E6A2-CW5C | |
|---|---|---|---|---|
| Power supply voltage | 5 VDC -5% to 12 V +10%, ripple (p-p): 5% max.  | 
                12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max.  | 
              ||
| Current consumption *1 | 30 mA max. | 20 mA max. | ||
| 
                  Resolution (pulses/rotation)  | 
                100, 200, 360, 500 | |||
| Output phases | Phases A and B | |||
| Output configuration | Voltage output | NPN open-collector output | ||
| Output capacity | Output resistance: 2 kΩ Output current: 20 mA max. Residual voltage: 0.4 V max. (Output current: 20 mA max.)  | 
                Applied voltage: 30 VDC max. Sink current: 30 mA max. Residual voltage: 0.4 V max. (at sink current of 30 mA)  | 
              ||
| 
                  Maximum response frequency *2  | 
                30 kHz | |||
| 
                  Phase difference between outputs  | 
                Phase difference between phases A and B: 90°±45° | |||
| Output duty factor | --- | |||
| 
                  Rise and fall times of output  | 
                1.0 μs max. (Cable length:  500 mm, Sink current: 10 mA)  | 
                1.0 μs max. (Cable length: 500 mm, Control output voltage: 5 V, Load resistance: 1 kΩ)  | 
              ||
| Starting torque | 1 mNm max. | |||
| Moment of inertia | 1 × 10-7 kgm2 max. | |||
| 
                  Shaft loading  | 
                Radial | 10 N | ||
| Thrust | 50 N | |||
| 
                  Maximum permissible speed  | 
                5,000 r/min | |||
| 
                  Ambient temperature range  | 
                Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing) | |||
| Ambient humidity range | Operating/storage: 35% to 85% (with no condensation) | |||
| Insulation resistance | 20 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection *3 | IEC 60529 IP50 | |||
| Connection method | Pre-wired Models (Standard cable length: 500 mm) | |||
| Material | Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron | |||
| Weight (packed state) | Approx. 35 g | |||
| Accessories | Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual | |||
| Model | E6A2-CS3E | E6A2-CS3C | E6A2-CS5C | |
|---|---|---|---|---|
| Power supply voltage | 5 VDC -5% to 12 V +10%, ripple (p-p): 5% max.  | 
                12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max.  | 
              ||
| Current consumption *1 | 30 mA max. | 20 mA max. | ||
| 
                  Resolution (pulses/rotation)  | 
                10, 20, 60, 100, 200, 300, 360, 500 | |||
| Output phases | Phase A | |||
| Output configuration | Voltage output | NPN open-collector output | ||
| Output capacity | Output resistance: 2 kΩ Output current: 20 mA max. Residual voltage: 0.4 V max. (Output current: 20 mA max.)  | 
                Applied voltage: 30 VDC max. Sink current: 30 mA max. Residual voltage: 0.4 V max. (at sink current of 30 mA)  | 
              ||
| 
                  Maximum response frequency *2  | 
                30 kHz | |||
| 
                  Phase difference between outputs  | 
                --- | |||
| Output duty factor | 50±25% | |||
| 
                  Rise and fall times of output  | 
                1.0 μs max. (Cable length: 500 mm, Sink current: 10 mA)  | 
                1.0 μs max. (Cable length: 500 mm, Control output voltage: 5 V, Load resistance: 1 kΩ)  | 
              ||
| Starting torque | 1 mNm max. | |||
| Moment of inertia | 1 × 10-7 kgm2 max. | |||
| 
                  Shaft loading  | 
                Radial | 10 N | ||
| Thrust | 50 N | |||
| 
                  Maximum permissible speed  | 
                5,000 r/min | |||
| 
                  Ambient temperature range  | 
                Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing) | |||
| Ambient humidity range | Operating/storage: 35% to 85% (with no condensation) | |||
| Insulation resistance | 20 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection *3 | IEC 60529 IP50 | |||
| Connection method | Pre-wired Models (Standard cable length: 500 mm) | |||
| Material | Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron | |||
| Weight (packed state) | Approx. 35 g | |||
| Accessories | Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual | |||
							last update: February 18, 2013