Item
Model |
G4Q |
G9B |
|
Appearance |
 |
 |
|
Features |
Unique ratchet mechanism assures
positive alternatetransfer/switching operation. |
Ideal for controlling pumps and
production lines with six or twelve stepping circuits. |
|
Contact Ratings |
Contact form |
DPDT |
SPST-NO |
|
Mechanism |
Single |
Single |
|
Material |
Ag |
Ag-alloy |
|
Rated Load *
(Resistive Load) |
5A at 220 VAC /24 VDC,
500,000 steps min. |
2A at 250 VAC/ 30 VDC |
|
Maximum switched
current |
5A |
2A |
|
Failure rate
(reference value) |
6 to 100 VDC
6 to 200/(220) VAC |
10 mA at 5 VDC |
|
Coil Ratings |
Rated Voltage |
100 mA at 5 VDC |
100 VAC, 200 VAC, 24 VDC |
|
Power consumption
(approx.) |
3.9 W (DC)
6.4 VA (AC) |
24 VDC 90 mA max.
100 or 200 VAC
120 mA max. |
|
Endurance |
Mechanical |
5 x 106
(step) |
10 x 106
(step) |
|
Electrical |
500 x 10³ (step) |
300 x 10³ (step) |
|
Dielectric Strength |
Between coil and
contacts |
2,000 VAC
for 1 min. |
1,500 VAC, 50/60 Hz for 1 min. between the power supply, C, S, and
R terminals and other terminals
1,500 VAC, 50/60 Hz for 1 min. between the terminals, except the
alarm output terminals and power supply terminals |
|
Between contacts of
different polarities |
2,000 VAC
for 1 min. |
|
Between contacts of
same polarity |
1,000 VAC
for 1 min. |
|
Between set and
reset coil |
-- |
-- |
|
Ambient temperature |
–10°C to 55°C |
–25°C to
55°C |
|
Function |
-- |
• Alarm indicator, operating
indicator
|
|
Sealing |
• Open
• Cased (unsealed) |
Closed |
|
Terminal
construction ** |
 |
 |
|
Approved standards |
-- |
-- |