|
D4NS
Safety-door Switch |
 |
Lineup includes three-contact models with
2NC/1NO and 3NC contact forms and MBB models in addition
to the previous 1NC/1NO and 2NC contact forms.
M12-connector models are available, saving on labor
and simplifying replacement.
Standardized gold-clad contacts provide high
contact reliability. Can be used with both standard
loads and microloads.
Variety of metal heads available.
|
EN60947-5-1
GS-ET-15
UL508
CSA C22.2
No.14
GB14048.5 |
TάV
SάD
UL
UL (cUL)
CQC
KOSHA*
|
|
D4GS-N
Slim Safety-door Switch |
|
Slim design with a width of only 17mm. (three-terminal
contact)
Reversible design allowing either front or rear
mounting.
Built-in switches with two- or three terminal contact
construction are available.
Degree of protection: IP67
|
EN60947-5-1
GS-ET-15
UL508
CSA C22.2
No.14
GB14048.5 |
TάV
SάD
UL
UL (cUL)
CQC
|
|
D4BS
Safety-door Switch |
|
Direct opening mechanism pulls the
contacts apart from each other if any abnormality, such as contact
welding, should occur in the contact area.
Wide operating temperature range from -40° to 80°C
Degree of protection of the switch box: IP67 (EN60947-5-1).
|
EN60947-5-1
GS-ET-15
UL508
CSA C22.2
No.14
GB14048.5 |
TάV, Rheinland
BIA
SUVA
UL
CSA
CQC
|
|
D4SL
Guard Lock Safety-door Switch |
|
Two types of models: Connector models to reduce wiring
labor and models with removable terminal blocks.
Metal Heads for superior strength and durability.
Reliable holding force: 1,300 N
Model with six contacts enables monitoring both door
open/close status and solenoid ON/OFF status.
|
EN60947-5-1
GS-ET-19
UL508
CSA C22.2
No.14
|
TάV
SάD
UL
CQC
KOSHA
|
|
D4GL
Guard Lock Safety-door Switch |
|
Slim safety-door switch with an electromagnetic lock
and unlock mechanism.
Built-in switches with four- or five-terminal contact
construction are available.
Capable of holding force of 1,000 N min. (224 lbf)
Can be used with either standard loads or microloads.
Line-up includes models with a conduit size of M20.
|
EN60947-5-1
GS-ET-19
UL508
CSA C22.2
No.14
GB14048.5 |
TάV
SάD
UL
UL (cUL)
CQC
KOSHA*
|
|
D4JL
Guard Lock Safety-door Switch |
|
World's Top* Holding Force of 3,000 N min. *For
plastic models.
Two safety circuits and two monitor contacts provide an array of monitoring patterns.
Models with trapped keys/rear release button prevent
workers from being locked in hazardous work areas.
Degree of protection: IP67.
|
EN60947-5-1
GS-ET-19
UL508
CSA C22.2
No.14
GB14048.5
|
TάV
SάD
UL
UL (cUL)
CQC
KOSHA*
|
|
D4NL
Guard Lock Safety-door Switch |
|
Built-in switches with four- or five-terminal contact
construction are available.
Capable of holding force of 1,300 N min. (292.25 lbf)
Can be used with either standard loads or microloads.
Line-up includes models with a conduit size of M20.
Degree of protection: IP67.
|
EN60947-5-1
GS-ET-19
UL508
CSA C22.2
No.14
GB14048.5 |
TάV
SάD
UL
UL (cUL)
CQC
KOSHA*
|
|
D4BL
Guard Lock Safety-door Switch |
|
Doors are locked mechanically when an
Operation Key is inserted.
Mechanical lock is released when voltages are applied to the
solenoid.
Auxiliary release key ensures easy maintenance and unlocks the
door in the case of a power failure.
Degree of protection: IP67.
|
EN60947-5-1
GS-ET-19
UL508
CSA C22.2
No.14
GB14048.5 |
TάV, Rheinland
UL
CSA
CQC
|
|
D4NH
Safety-door Hinge Switch |
 |
Lineup includes three-contact models with 2NC/1NO and
3NC contact forms and MBB models in addition to the
previous 1NC/1NO and 2NC contact forms.
M12-connector models are available, saving on labor
and simplifying replacement.
Standardized gold-clad contacts provide high
contact reliability. Can be used with both standard
loads and microloads.
|
EN60947-5-1
GS-ET-15
UL508
CSA C22.2
No.14 GB14048.5
Application Standard No: EN81 (Lifts)
EN115 (Escalators, Conveyors) |
TάV
SάD
UL
UL (cUL)
CQC
|
|
D40A/G9SX-NS
Compact Non-contact
Door Switch/Flexible Safety Unit |
 |
Stable operation reduces Controller errors caused by unstable
doors.
Connect up to 30 Non-contact Door Switches with LED indicators
to one Controller.
Reversible switch provides flexibility in installation.
Two-color LED indicator enables easier maintenance by
identification of door status and cable disconnections.
Both Non-contact Door Switches and conventional Key-type
Safety-door Switches can be input to one Controller, saving space.
Category 3/PLd |
EN50178
IEC/EN60204-1
ISO13849-1
IEC/EN61508
IEC/EN60947-5-3
IEC/EN61000-6-2
IEC/EN61000-6-4
PDF-M
UL508
CAN/CSA C22.2
No.14
|
TάV SάD
UL (cUL)
KOSHA
|
|
D40Z
Compact Non-contact
Door Switch |
 |
A Non-contact Door Switch that complies with ISO 13849-1 Safety
Category 4/PLe.
Confirm the current status at the Switch.
Connect up to 30 Switches in series to one controller and
maintain Safety Category 4/PLe. |
EN50178
IEC/EN60204-1
ISO13849-1
IEC/EN61508
IEC/EN60947-5-3
EN55011
IEC/EN61000-6-4
EN1088
UL508
CAN/CSA C22.2
No.14
|
TάV SάD
UL (cUL)
|
|
D4SL-SK10
D4GL-SK10
D4SL-/D4GL-mounting Slide
Keys |
|
The lockout key prevents operators from becoming trapped inside
hazardous areas.
The vertical D4SL/D4GL Guard Lock Safety-door Switch can be easily
mounted on 40 Χ 40 mm aluminum frames.
The plastic material makes the Slide Key suitable for
lightweight doors.
|
- |
- |
|
D4NS-SK/ D4JL-SK
D4NS/D4JL-mounting Slide
Keys |
|
Safety-door Switch attachments fit doors on aluminum frames as
small as 20 x 20 mm and frames that are large enough to enclose
robotics.
Shortens the design time for the door switch attachment.
|
- |
- |