E5Z Series Digital Controllers:
|
Item
Model |
E5CZ |
E5EZ |
E5AZ |
E5EZ-PRR |
|
Appearance |
 |
 |
 |
 |
|
No. of loops |
1 |
|
Size |
48 × 48 mm (front mount) |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
48 × 96 mm (front mount) |
|
Input accuracy |
±0.5% |
|
Input type |
Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100;
Infrared temperature sensor;
Voltage input: 0 to 50 mV |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
|
Sampling rate |
250
ms |
|
Power supply |
Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or
24 VDC |
Universal AC
Power (100 to 240 VAC, 50/60 Hz) |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
100 to 240 VAC: 7.5 VA max.
24 VAC: 5.5 VA max.
24 VDC: 3.5 W max. |
100 to 240
VAC: 8.5 VA max.
24 VAC: 6 VA max.
24 VDC: 4 W max. |
10 VA (10W) |
|
Control type |
ON/OFF or 2 PID control (with auto-tuning) |
2 PID control
(with autotuning) |
|
Control mode |
Heating/cooling control |
Position proportional control only
|
|
Control output |
Relay output: SPST; SSR driver (voltage); Current output
|
Relay output:
2 nos of relays (SPST), for open and close function |
|
Auxiliary output |
Not
supported |
|
Event output |
2
max. |
|
Logic operation |
Not
supported |
|
Transfer output |
Not
supported |
|
Remote setpoint |
Not
supported |
|
Potentiometer |
Not
supported |
100 to 2500 Ω
|
|
Heater / SSR failure
detection |
Heater detection (1 CT only)
|
Not supported |
|
Setting method |
Digital setting using front panel key or software access
|
|
Indication method |
11-segment 2-line digital and individual indicator |
7-segment
3-line digital and single lighting indicator |
|
Setpoint program |
Not
supported |
|
Bank switching |
Not
supported |
|
Communication type |
RS-485
communication type, supporting Compoway/F or Modbus |
RS-232 or RS-485 communication type, supporting Compoway/F or
Modbus |
|
Alarm |
2 alarms |
3 alarms |
2 alarms |
|
Configuration
software |
USB-Serial
conversion cable with Thermo Mini software
|
|
|
E5N Series Digital Controllers:
|
Item
Model |
E5GN |
E5CN |
E5EN |
E5AN |
|
Appearance |
 |
 |
 |
 |
|
No. of loops |
1 |
|
Size |
48 × 24 mm (panel mount) |
48 × 48 mm (front mount) |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
|
Input accuracy |
Thermocouple:
±0.3%; Pt/analog: ±0.2% |
|
Input type |
Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100;
Infrared temperature sensor; Voltage input: 0 to 50 mV |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
|
Sampling rate |
250
ms |
|
Power supply |
Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or
24 VDC |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
100 to 240
VAC: 5.5 VA max.
24 VAC: 3 VA max.
24 VDC: 2 W max. |
100 to 240 VAC: 7.5 VA max.
24 VAC: 5 VA max.
24 VDC: 3 W max. |
100 to 240
VAC: 10 VA max.
24 VAC: 5.5 VA max.
24 VDC: 4 W max. |
|
Control type |
ON/OFF or 2 PID control (with auto-tuning) |
|
Control mode |
Standard or heating/cooling control |
|
Control output |
Relay output:
SPST; SSR driver (voltage); Current output |
|
Auxiliary output |
2 max. |
3 max. |
|
Event output |
2
max. |
|
Logic operation |
8
operations |
|
Transfer output |
Supported on
control OUT1 |
|
Remote setpoint |
Not
supported |
|
Potentiometer |
Not
supported |
|
Heater / SSR failure
detection |
1
CT input for heater and SSR failure detection |
2 CT inputs for heater and SSR failure detection
|
|
Setting method |
Digital setting using front panel key or software access
|
|
Indication method |
11-segment 1-line digital and single lighting indicator |
11-segment 2-line digital and
individual indicator |
11-segment 3-line digital and
individual indicator |
|
Setpoint program |
Not
supported |
|
Bank switching |
Not
supported |
|
Communication type |
RS-232 or RS-485 communication type, supporting Compoway/F or
Modbus |
|
Alarm |
2 alarms |
|
Configuration
software |
USB-Serial conversion cable with CX-Thermo software
|
E5N Series Advanced Digital Controllers:
|
Item
Model |
E5CN-H |
E5EN-H |
E5AN-H |
|
Appearance |
 |
 |
 |
|
No. of loops |
1 |
|
Size |
48 × 48 mm (front mount) |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
|
Input accuracy |
±0.1% |
|
Input type |
Fully universal inputs can be selected from Thermocouple, RTD,
VDC, or mA |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
|
Sampling rate |
60
ms |
|
Power supply |
Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or
24 VDC |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
100 to 240 VAC: 8.5 VA max.
24 VAC: 5.5 VA max.
24 VDC: 3.5 W max. |
100 to 240 VAC: 12 VA max.
24 VAC: 8.5 VA max.
24 VDC: 5.5 W max. |
|
Control type |
ON/OFF or 2 PID control (with auto-tuning) |
|
Control mode |
Standard or heating/cooling control |
Standard, heating/cooling or
position proportional control |
|
Control output |
Relay output: SPST; SSR driver (voltage); Current output
|
|
Auxiliary output |
2
max. |
3
max. |
|
Event output |
2
max. |
4 max. |
|
Logic operation |
8
operations |
|
Transfer output |
Supported |
|
Remote setpoint |
Not
supported |
Supported |
|
Potentiometer |
Not
supported |
Supported |
|
Heater / SSR failure
detection |
2
CT inputs for heater and SSR failure detection |
|
Setting method |
Digital setting using front panel key or software access
|
|
Indication
method |
11-segment 2-line digital and individual indicator, with 5-digit
display
|
11-segment 3-line digital and individual indicator, with 5-digit
display |
|
Setpoint program |
1 ×
8 segment (bank switching) |
|
Bank switching |
8
banks |
|
Communication type |
RS-232 or
RS-485 communication type, supporting Compoway/F, Sysway or Modbus |
|
Alarm |
2 alarms |
3 alarms |
|
Configuration
software |
USB-Serial
conversion cable with CX-Thermo software
|
E5K Series Programmable Type Controllers:
|
Item
Model |
E5CK |
E5EK |
E5AK |
|
Appearance |
 |
 |
 |
|
No. of loops |
1 |
|
Size |
48 × 48 mm (front mount) |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
|
Input accuracy |
±0.3% |
|
Input type |
Fully universal inputs can be selected from Thermocouple, RTD, VDC
or mA |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
|
Sampling rate |
100
ms |
|
Power supply |
Universal AC Power (100 to 240 VAC, 50/60 Hz) |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
15 VA max. |
16 VA max. |
|
Control type |
ON/OFF or 2 PID control (with auto-tuning) |
|
Control mode |
Standard or heating/cooling control |
Standard, heating/cooling or
position proportional control |
|
Control output |
Relay output: SPST; SSR driver (voltage); Current output
|
|
Auxiliary output |
1 |
|
Event output |
Supported |
|
Logic operation |
Not
supported |
|
Transfer output |
Supported |
|
Remote setpoint |
Not
supported |
Supported |
|
Potentiometer |
Not
supported |
Supported |
|
Heater / SSR failure
detection |
Not
supported |
Supported |
|
Setting method |
Digital setting using front panel key
|
|
Indication
method |
7-segment 2-line digital display and LEDs
|
|
Setpoint program |
4 programs ×
64 segments |
|
Bank switching |
Not
supported |
|
Communication type |
RS-232,
RS-422 or RS-485 communication type, supporting Modbus |
|
Alarm |
No boundary |
|
Configuration
software |
Not supported |
E5R Series High-performance Controllers:
|
Item
Model |
E5ER |
E5AR |
E5ER-T |
E5AR-T |
|
Appearance |
 |
 |
 |
 |
|
No. of loops |
2 |
4 |
2 |
4 |
|
Size |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
48 × 96 mm (front mount) |
96 × 96 mm (front mount) |
|
Input accuracy |
±0.1% |
|
Input type |
Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100;
Current Input: 4 to 20 mA DC, 0 to 20 mA DC; Voltage input: 0 to 5
VDC, 1 to 5 VDC, 0 to 10 VDC |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
|
Sampling rate |
50 ms |
|
Power supply |
Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or
24 VDC |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
100 to 240
VAC: 17 VA
24 VAC/VDC: 11 VA/7 W |
100 to 240
VAC: 22 VA
24 VAC/VDC: 15 VA/10 W |
100 to 240
VAC: 17 VA
24 VAC/VDC: 11 VA/7 W |
100 to 240
VAC: 22 VA
24 VAC/VDC: 15 VA/10 W |
|
Control type |
2 PID control (with auto-tuning) |
|
Control mode |
Standard, heating/cooling or
position-proportional control |
|
Control output |
Relay output: SPST; SSR driver (voltage); Current output
|
|
Auxiliary output |
4 max. |
|
Event output |
6
max. |
|
Logic operation |
Math functions |
|
Transfer output |
Supported |
|
Remote setpoint |
Supported |
|
Potentiometer |
Supported |
|
Heater / SSR failure
detection |
Not
supported
|
|
Setting method |
Digital setting using front panel key or software access
|
|
Indication method |
7-segment
3-line digital and single lighting indicator |
|
Setpoint program |
1 × 8
segments (bank switching) |
32 programs ×
256 segments |
|
Bank switching |
8
banks |
|
Communication type |
RS-485
communication type, supporting Compoway/F, Modbus and DeviceNet |
|
Alarm |
No boundary |
|
Configuration
software |
CX-Thermo
through RS-485 terminal
|
Multi-loop Modular Controllers:
|
Item
Model |
EJ1 |
E5ZN |
E5ZN-DRT |
|
Appearance |
 |
 |
 |
|
No. of loops |
4/module |
2/module |
DeviceNet module |
|
Size |
HFU: 31 × 95.4 mm;
End Unit: 15.7 × 95.4 mm (In-Panel DIN Rail) |
Each module:
130 × 30 mm (In-Panel DIN Rail) |
--- |
|
Input accuracy |
±0.5% |
--- |
|
Input type |
Fully universal inputs can be selected from Thermocouple, RTD, VDC
or mA |
Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100;
Infrared temperature sensor; Voltage input: 0 to 50 mV |
|
Input impedance |
Current input: 150 Ω, Voltage input: 1 MΩ |
--- |
|
Sampling rate |
250
ms |
500 ms |
--- |
|
Power supply |
24
VDC |
|
Operating power |
85% to 110% of rated supply voltage |
|
Power consumption |
5 W |
3 W |
|
Control type |
ON/OFF or 2 PID control |
--- |
|
Control mode |
Standard or heating/cooling control |
--- |
|
Control output |
SSR driver, Transistor, Current output
|
--- |
|
Auxiliary output |
Supported |
--- |
|
Event output |
Supported |
--- |
|
Logic operation |
Supported |
Not
supported |
--- |
|
Transfer output |
Supported |
--- |
|
Remote setpoint |
Not
supported |
--- |
|
Potentiometer |
Not
supported |
--- |
|
Heater / SSR failure
detection |
Not
supported |
Heater burnout alarm |
--- |
|
Setting method |
Setting through software |
By setting display unit |
--- |
|
Indication
method |
Not
supported |
--- |
|
Setpoint program |
Not
supported |
--- |
|
Bank switching |
8
banks |
Not
supported |
--- |
|
Communication type |
RS-422, RS-485, RS-232, Devicenet, supporting Compoway/F or Modbus |
RS-485 communication
type,
supporting Modbus |
DeviceNet |
|
Alarm |
No
boundary |
--- |
|
Configuration
software |
USB-Serial Conversion cable with
CX-Thermo software |
--- |
Other Controllers:
|
Item
Model |
E5C2 |
E5CS /
E5CSV /
E5CSZ |
|
Appearance |
 |
 |
|
No. of loops |
1 |
|
Size |
48 × 48 mm (front mount) |
|
Input accuracy |
±2% |
±0.5% |
|
Input type |
Thermocouple J or K, RTD Pt-100 and Thermistor THE |
Thermocouple K, J, L, T, U, N or R,
RTD Pt-100, JPt-
100, Thermistor: E52-THE |
|
Input impedance |
--- |
|
Sampling rate |
--- |
500
ms |
|
Power supply |
100/110/120 VAC or 200/220/240 VAC |
Universal AC Power (100 to 240 VAC, 50/60 Hz)
24 VAC/VDC |
|
Operating power |
90% to 110% of rated supply voltage |
85% to 110% of rated supply voltage |
|
Power consumption |
Approx. 2 VA |
100 to 240
VAC: 5 VA
24 VAC/VDC: 3 VA/2 W |
|
Control type |
ON/OFF or position-proportional control |
ON/OFF or 2 PID control (with
automatic PID setting) |
|
Control mode |
Standard |
|
Control output |
Relay output: SPST
|
Relay output: SPST; SSR driver (voltage) |
|
Auxiliary output |
Not
supported |
|
Event output |
Not
supported |
|
Logic operation |
Not
supported |
|
Transfer output |
Not
supported |
|
Remote setpoint |
Not
supported |
|
Potentiometer |
Not
supported |
|
Heater / SSR failure
detection |
Not
supported |
|
Setting method |
Analog setting |
Digital setting using front panel
key and DIP switch setting |
|
Indication method |
No
indication |
7-segment single-line digital and
deviation indicator |
|
Setpoint program |
Not
supported |
|
Bank switching |
Not
supported |
|
Communication type |
Not
supported |
|
Alarm |
Not supported |
2 alarms
(except E5CSZ) |
|
Configuration
software |
Not supported |
top
|
|
 |
|