Relays with Forcibly Guided Contacts
last update: May 20, 2024
Item | Rated current (mA) | Coil resistance (Ω) | Max. voltage (V) | Power consumption (mW) |
---|---|---|---|---|
Rated voltage | ||||
12 VDC | 30 | 400 | 110% | Approx. 360 |
18 VDC | 20 | 900 | ||
21 VDC | 17.1 | 1,225 | ||
24 VDC | 15 | 1,600 | ||
48 VDC | 7.5 | 6,400 | ||
110 VDC | 3.8 | 28,810 | Approx. 420 |
Item | Rated current (mA) | Coil resistance (Ω) | Max. voltage (V) | Power consumption (mW) |
---|---|---|---|---|
Rated voltage | ||||
12 VDC | 41.7 | 288 | 110% | Approx. 500 |
18 VDC | 27.8 | 648 | ||
21 VDC | 23.8 | 882 | ||
24 VDC | 20.8 | 1,152 | ||
48 VDC | 10.4 | 4,606 | ||
110 VDC | 5.3 | 20,862 | Approx. 580 |
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.
Load | Resistive load |
---|---|
Rated load | 6 A at 250 VAC, 6 A at 30 VDC |
Rated carry current | 6 A |
Max. switching voltage | 250 VAC, 125 VDC |
Max. switching current | 6 A |
Contact materials | Au plating + Ag alloy |
Contact resistance *1 | 100 mΩ max. | |
---|---|---|
Operating time *2 | 20 ms max. | |
Response time *3 | 10 ms max. | |
Release time *2 | 20 ms max. | |
Must operate voltage | 75% max. | |
Must release voltage | 10% min. | |
Maximum
operating frequency |
Mechanical | 36,000 operations/h |
Rated load | 1,800 operations/h | |
Insulation resistance *4 | 1,000 MΩ min. | |
Dielectric
Strength *5 *6 |
Between coil
and contacts |
4,000 VAC, 50/60 Hz for 1 min. |
Between
contacts of different olarity |
4,000 VAC, 50/60 Hz for 1 min. (except for followings)
4 poles (for poles 3-4 in 4-pole Relays), 6 poles (for poles 3-5, 4-6, and 5-6 in 6-pole Relays): 2,500 VAC, 50/60 Hz for 1 min. |
|
Between
contacts of the same polarity |
1,500 VAC, 50/60 Hz for 1 min. | |
Vibration resistance | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |
Shock
resistance |
Destruction | 1,000 m/s2 |
Malfunction | 100 m/s2 | |
Durability
*7 |
Mechanical | 10,000,000 operations min. (at approx. 36,000 operations/h) |
Electrical | 100,000 operations min. (at the rated load) | |
Inductive load switching
capability *8 (IEC60947-5-1) |
AC15 240 VAC, 2 A
DC13 24 VDC, 1 A/48 VDC, 0.5 A/110 VDC, 0.2 A |
|
Failure rate (P level)
(reference value *9) |
5 VDC, 1 mA | |
Ambient operating
temperature *10 |
12 to 48 VDC: -40 to 85°C (with no icing or condensation)
110 VDC: -40 to 60°C (with no icing or condensation) |
|
Ambient operating humidity | 5% to 85% | |
Weight | 4 poles: Approx. 22 g
6 poles: Approx. 25 g |
Model | Push-In Plus terminals | Screw terminals | PCB terminals | ||||
---|---|---|---|---|---|---|---|
4 poles | 6 poles | 4 poles | 6 poles | 4 poles | 6 poles | ||
P7SA-10F-ND-PU | P7SA-14F-ND-PU | P7SA-10F(-ND) | P7SA-14F(-ND) | P7SA-10P | P7SA-14P | ||
Ambient operating temperature | • With operation indicator LED/built-in diode
P7SA-[]F-ND(-PU): -20 to +70°C • Without operation indicator LED/built-in diode P7SA-[]F: -40 to +85°C (with no icing or condensation) |
-40 to +85°C
(with no icing or condensation) |
|||||
Ambient operating humidity | 25% to 85% | 5% to 85% | |||||
Continuous carry current | 6 A *1 | ||||||
Dielectric
strength |
Between coil
and contact terminals |
4,000 VAC for 1 min. | 2,500 VAC for 1 min. | ||||
Between contact
terminals of different polarity |
2,500 VAC for 1 min. | ||||||
Between contact
terminals of same polarity |
1,500 VAC for 1 min. | ||||||
Insulation resistance | 1,000 MΩ min. *2 | ||||||
Weight | Approx. 58 g | Approx. 70 g | Approx. 44 g | Approx. 59 g | Approx. 9 g | Approx. 10 g |
*1. When operating the P7SA-[]F-ND-PU at a temperature between 50 and 70°C, reduce the continuous current
(6 A at 50°C or less) by 0.25 A for each degree above 50°C.
When operating the P7SA-[]F-ND at a temperature between 50 and 70°C, reduce the continuous current
(6 A at 50°C or less) by 0.3 A for each degree above 50°C.
When operating the P7SA-[]F at a temperature between 50 and 85°C, reduce the continuous current
(6 A at 50°C or less) by 0.1 A for each degree above 50°C.
*2. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
Application | Applicable
sockets |
Models | Maximum
carry current |
Ambient operating
temperature |
Ambient operating
humidity |
---|---|---|---|---|---|
Crossover wiring of
contact terminals (bottom) |
P7SA-[]F-ND-PU | XW5S-P2.5-2[] | 24 A | -40 to 55°C | 5% to 95% |
XW5S-P2.5-3[] | |||||
XW5S-P2.5-4[] | |||||
XW5S-P2.5-5[] |
Models | Ratings | Standard number | Certification No. | Operating coil | Contact ratings |
---|---|---|---|---|---|
G7SA-2A2B | 12, 18, 21, 24, 48, 110 VDC | EN/IEC 61810-1
Electromagnetic relay EN 61810-3 Relays with forcibly guided contacts |
125547 | 12, 18, 21, 24, 48, 110 VDC | 6 A, 240 VAC (Resistive)
6 A, 30 VDC (Resistive) |
G7SA-3A1B | |||||
G7SA-3A3B | |||||
G7SA-4A2B | |||||
G7SA-5A1B |
Models | Category | Listed/Recognized | Contact ratings | Operating Coil ratings |
---|---|---|---|---|
G7SA-2A2B | E41515 | Recognized | 6 A, 250 VAC (Resistive)
6 A, 30 VDC (Resistive) |
12, 18, 21, 24, 48, 110 VDC |
G7SA-3A1B | ||||
G7SA-3A3B | ||||
G7SA-4A2B | ||||
G7SA-5A1B |
Models | Class number | File No. | Contact ratings | Operating Coil ratings |
---|---|---|---|---|
G7SA-2A2B | 3211-07 | LR35535 | 6 A, 250 VAC (Resistive)
6 A, 30 VDC (Resistive) |
12, 18, 21, 24, 48, 110 VDC |
G7SA-3A1B | ||||
G7SA-4A2B | ||||
G7SA-5A1B |
Models | Applicable standard number |
---|---|
G7SA-2A2B DC24 | KS C IEC 61810-1 |
G7SA-3A1B DC24 | |
G7SA-3A3B DC24 | |
G7SA-4A2B DC24 | |
G7SA-5A1B DC24 |
Models | Standard number | Certification No. |
---|---|---|
G7SA | GB/T, 21711.1 | CQC14002119869 |
Models | EMC Directive | Low Voltage Directive | Machinery Directive |
---|---|---|---|
P7SA (Excluding -P type) | Not applicable | Applicable | Not applicable |
P7SA-PU | Not applicable | Applicable | Not applicable |
The CE compliance declaration was made in combination with the Safety Relay.
Models | Ratings | Standard number | Certification No. |
---|---|---|---|
P7SA | --- | EN61984 | 40007586 |
Models | Ratings | Standard number | Certification No. |
---|---|---|---|
P7SA-PU | --- | EN61984 | R50356981 |
Models | Category | Listed/Recognized |
---|---|---|
P7SA | SWIV2 | Recognized |
P7SA-PU | SWIV2, SWIV8 | Recognized |
Models | Class number | File No. |
---|---|---|
P7SA | 3211-07, 3211-87 | LR35535 |
P7SA-PU | 3211-07, 3211-87 | LR35535 |