Rectangular Standard Proximity Sensor
last update: May 10, 2017
| Model | TL-Q5MD[] | TL-N7MD[] | TL-N12MD[] | TL-N20MD[] | |
|---|---|---|---|---|---|
| Sensing distance | 5 mm ±10% | 7 mm ±10% | 12 mm ±10% | 20 mm ±10% | |
| Set distance | 0 to 4 mm | 0 to 5.6 mm | 0 to 9.6 mm | 0 to 16 mm | |
| Differential travel | 10% max. of sensing distance | ||||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
| Standard sensing object | Iron, 18 × 18 ×
1 mm |
Iron, 30 × 30 ×
1 mm |
Iron, 40 × 40 ×
1 mm |
Iron, 50 × 50 ×
1 mm |
|
| Response frequency * | 500 Hz | 300 Hz | |||
| Power supply voltage
(operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||
| Leakage current | 0.8 mA max. | ||||
| Control
output |
Load current | 3 to 100 mA | |||
| Residual
voltage |
3.3 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
| Indicators | D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red) |
||||
| Operation mode (with
sensing object approaching) |
D1 Models: NO, D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
||||
| Protection circuits | Load short-circuit protection, Surge suppressor | ||||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC for 1 min between current-carrying parts and case | ||||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance | Destruction: 500
m/s2 3 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m) | ||||
| Weight (packed state) | Approx. 85 g | Approx. 165 g | Approx. 235 g | Approx. 330 g | |
| Materials | Case | Heat-resistant ABS | |||
| Sensing
surface |
|||||
| Accessories | Instruction manual | Mounting Bracket,
Mounting phillips screws (M4 × 25), Instruction manual |
Mounting Bracket,
Mounting phillips screws (M4 × 30), Instruction manual |
Mounting Bracket,
Mounting phillips screws (M5 × 40), Instruction manual |
|
| Model | TL-Q2MC1 | TL-Q5MC[]/TL-Q5MB1 | |
|---|---|---|---|
| Sensing distance | 2 mm ±15% | 5 mm ±10% | |
| Set distance | 0 to 1.5 mm | 0 to 4 mm | |
| Differential travel | 10% max. of sensing distance | ||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||
| Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 15 × 15 × 1 mm | |
| Response time | --- | 2 ms max. | |
| Response frequency * | 500 Hz | ||
| Power supply voltage
(operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||
| Current consumption | 15 mA max. at 24 VDC (no-load) | 10 mA max. at 24 VDC | |
| Control
output |
Load current | NPN open collector
100 mA max. at 30 VDC max. |
TL-Q5MC[]:
NPN open collector, 50 mA max. at 30 VDC max. TL-Q5MB[]: PNP open collector, 50 mA max. at 30 VDC max. |
| Residual voltage | 1 V max. (under load current of 100 mA with
cable length of 2 m) |
1 V max. (under load current of 50 mA with
cable length of 2 m) |
|
| Indicators | Detection indicator (red) | ||
| Operation mode (with
sensing object approaching) |
NO | B1/C1 Models: NO
C2 Models: NC |
|
| Refer to the timing charts under DC 3-Wire Models on Catalog for details. | |||
| Protection circuits | Reverse polarity protection, Surge suppressor | ||
| Ambient temperature range | Operating/Storage: -10 to 60°C
(with no icing or condensation) |
Operating/Storage: -25 to 70°C
(with no icing or condensation) |
|
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||
| Temperature influence | ±10% max. of sensing distance at 23°C in
the temperature range of -10 to 60°C |
±20% max. of sensing distance at 23°C in
the temperature range of -25 to 70°C |
|
| Voltage influence | ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range | ||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-
carrying parts and case |
5 MΩ min. (at 500 VDC) between current-
carrying parts and case |
|
| Dielectric strength | 1,000 VAC for 1 min between current-
carrying parts and case |
500 VAC, 50/60 Hz for 1 min between
current-carrying parts and case |
|
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X,
Y, and Z directions |
Destruction: 200 m/s2 10 times each in X,
Y, and Z directions |
|
| Degree of protection | IEC 60529 IP67,
in-house standards: oil-resistant |
IEC IP67 | |
| Connection method | Pre-wired Models (Standard cable length: 2 m) | ||
| Weight (packed state) | Approx. 60 g | Approx. 90 g | |
| Materials | Case | Heat-resistant ABS | |
| Sensing surface | |||
| Accessories | Instruction manual | --- | |
| Model | TL-N5ME[]
TL-N5MY[] |
TL-N10ME[]
TL-N10MY[] TL-N10MF1 |
TL-N20ME[]
TL-N20MY[] |
|
|---|---|---|---|---|
| Sensing distance | 5 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
| Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 16 mm | |
| Differential travel | 15% max. of sensing distance | |||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
|||
| Standard sensing object | Iron, 30 × 30 × 1 mm | Iron, 40 × 40 × 1 mm | Iron, 50 × 50 × 1 mm | |
| Response frequency *1 | E/F Models: 500 Hz
Y Models: 10 Hz |
E Models: 40 Hz
Y Models: 10 Hz |
||
| Power supply voltage *2
(operating voltage range) |
E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz |
|||
| Current consumption | E/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC | |||
| Leakage current | Y Models: Refer to Engineering Data on Catalog. | |||
| Control
output |
Load current | E/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA |
||
| Residual voltage | E/F Models: 1 V max. (load current: 200 mA)
Y Models: Refer to Engineering Data on Catalog. |
|||
| Indicators | E/F Models: Detection indicator (red)
Y Models: Operation indicator (red) |
|||
| Operation mode (with
sensing object approaching) |
E1/F1/Y1 Models: NO
E2/Y2 Models: NC |
|||
| Refer to the timing charts under I/O Circuit Diagrams onCatalog for details. | ||||
| Protection circuits | E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor |
|||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
| Voltage influence | E/F Models:
±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range |
|||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
|||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
| Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
| Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
| Weight (packed state) | Approx. 190 g | Approx. 240 g | Approx. 340 g | |
| Materials | Case | Heat-resistant ABS | ||
| Sensing surface | ||||
| Accessories | E Models:
Mounting Bracket, Mounting phillips screws (M4 × 25), Instruction manual Y Models: Instruction manual |
E/F Models:
Mounting Bracket, Mounting phillips screws (M4 × 30), Instruction manual Y Models: Instruction manual |
E Models:
Mounting Bracket, Mounting phillips screws (M5 × 40), Instruction manual Y Models: Instruction manual |
|
last update: May 10, 2017