Power Relay
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 24, 2012
Rated voltage | Current | Coil
resistance |
Coil inductance
(ref. value) |
Must
operate |
Must
release |
Max.
voltage |
Power
con- sumption |
||
---|---|---|---|---|---|---|---|---|---|
50 Hz | 60 Hz | Armature
OFF |
Armature
ON |
% of rated voltage | |||||
6 VAC | 295 mA | 233 mA | 8.9 Ω | 0.048 H | 0.065 H | 80 %
max. |
30 %
min. |
110% | Approx.
1.4 VA |
24 VAC | 73 mA | 58 mA | 136 Ω | 0.691 H | 1.04 H | ||||
100/110 VAC | 17.7/
21.4 mA |
14/
16.8 mA |
2,200 Ω | 12.42/
12.38 H |
18/
16.4 H |
||||
200/220 VAC | 8.9/
10.8 mA |
7/
8.4 mA |
8,800 Ω | 42.2/
41.8 H |
72/
65.5 H |
||||
12 VDC | 88 mA | 136 Ω | 0.6 H | 1.0 H | 10 %
min. |
Approx.
1.1 W |
|||
24 VDC | 45 mA | 530 Ω | 2.7 H | 4.6 H | |||||
48 VDC | 22 mA | 2,200 Ω | 11 H | 19 H | |||||
100 VDC | 11.4 mA | 8,800 Ω | 43 H | 73 H |
Load | Resistive load (cosΦ = 1) | Inductive load (cosΦ = 0.4) (L/R = 7 ms) |
---|---|---|
Contact mechanism | Crossbar bifurcated | |
Contact material | Movable:AgAu-clad AgPd Fixed:AgPd |
|
Rated load | 0.3 A at 110 VAC 0.5 A at 24 VDC |
0.2 A at 110 VAC 0.3 A at 24 VDC |
Rated carry current | 2 A | |
Max. switching voltage | 250 VAC, 125 VDC | |
Max. switching current | AC: 0.7 A DC: 2 A |
AC: 0.5 A DC: 1 A |
Contact resistance (see note 2) | 100 mΩ max. |
---|---|
Operate time (see note 3) | 15 ms max. |
Release time (see note 3) | 15 ms max. |
Max. operating frequency | Mechanical: 18,000 operations/hour Electrical: 1,800 operations/hour (under rated load) |
Insulation resistance (see note 4) | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 1,500 VAC, 50/60 Hz for 1 minute between coil and contact and between contacts of different polarities (700 VAC between contacts of same polarities) |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
Shock resistance | Destruction: 1,000 m/s2 Malfunction: 100 m/s2 |
Error rate (level P) (Reference value) (see note 5) |
1 mA at 100 mVDC |
Endurance | Mechanical: 100,000,000 operations min. (at operating frequency of 18,000 operations/hour) Electrical: 5,000,000 operations min. (under rated load and at operating frequency of 1,800 operations/hour) (see note 6) |
Ambient temperature | Operating:-10°C to 40°C (with no icing or condensation) |
Ambient humidity | Operating:5% to 85% |
Weight | Approx. 39 g |
last update: September 24, 2012