Safety Key Selector Switch
last update: October 5, 2018
| Certification body | Standards | File No. |
|---|---|---|
| UL *1 | UL508, C22.2 No.14 | E41515 |
| TÜV SÜD | EN60947-5-1
(certified direct opening mechanism) |
Consult your OMRON representative for details. |
| CQC(CCC) | GB/T 14048.5 | |
| KOSHA | EN60947-5-1 |
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained. (Certification has been obtained for the Switch Unit only)
| Rated carry current
(A) |
Rated voltage
(V) |
Rated current (A) | |||
|---|---|---|---|---|---|
| AC15
(inductive load) |
AC12
(resistive load) |
DC13
(inductive load) |
DC12
(resistive load) |
||
| 10 | 24 VAC | 10 | 10 | --- | --- |
| 110 | 5 | 10 | |||
| 220 | 3 | 6 | |||
| 380 | 2 | 3 | |||
| 440 | 1 | 2 | |||
| 24 VDC | --- | --- | 1.5 | 10 | |
| 110 | 0.5 | 2 | |||
| 220 | 0.2 | 0.6 | |||
| 380 | 0.1 | 0.2 | |||
| Model | A22TK | |
|---|---|---|
| Allowable operating
frequency |
Mechanical | 30 operations/minute max. |
| Electrical | 30 operations/minute max. | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |
| Dielectric strength | Between terminals of same polarity | 2,500 VAC, 50/60 Hz for 1 min. |
| Between each terminal and ground | 2,500 VAC, 50/60 Hz for 1 min. | |
| Vibration resistance *1 | 10 to 55 Hz, 1.5-mm double amplitude (within 1 ms) | |
| Shock resistance | Destruction | 1000 m/s2 |
| Malfunction *1 | 250 m/s2 max. | |
| Durability | Mechanical | 100,000 operations min. |
| Electrical | 100,000 operations min. | |
| Ambient operating temperature *2 | 20 to +70°C | |
| Ambient operating humidity | 35% to 85%RH | |
| Ambient storage temperature | 40 to +70°C | |
| Degree of protection | IP65 *3 | |
| Electric shock protection class | Class II | |
| PTI (tracking characteristic) | 175 | |
| Degree of contamination | 3 (EN60947-5-1) | |
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been used and contact reliability for smaller loads may be
reduced.