Precision Thermo-Humidity Logger
last update: February 6, 2023
Model | ZN-THS17-S | ZN-THS17C-S * | ZN-THS11-S | ZN-THS11C-S * | |
---|---|---|---|---|---|
Temperature | Measurement range ∗1 | 0 to 60°C | -25 to 60°C | ||
Measurement precision ∗3 | ±0.3°C (at 25°C) | ||||
Resolution | 0.1°C | ||||
Long-term drift ∗4 | 0.1°C or less / year | ||||
Relative
humidity |
Measurement range ∗2 | 20 to 85% | 0 to 99% | ||
Measurement precision ∗3 | ±2.5% (at 25°C, 10 to 85%) | ||||
Resolution | 0.1% | ||||
Long-term drift ∗4 | 1.0% or less / year | ||||
Recommended storage
temperature range *5 |
10 to 50°C (with no condensation or icing) | ||||
Recommended storage
humidity range *5 |
20 to 60% (with no condensation or icing) | ||||
Weight (packaged) | Approx. 300 g | ||||
Accessories | Mounting screw (M3 x 8) x 1
Caps to secure cable (one for each, front and rear) |
Mounting screw (M3 x 8) x 1 |
* Please choose this form when you buy it with the calibration certificate.
∗1. Condensation may occur if the device is transferred quickly between locations with significant temperature differences. The device may not be able to measure humidity accurately if condensation occurs. If the product becomes wet due to condensation, allow the product to dry in a dry, room-temperature environment before use.
∗2. The device may not be able to measure humidity accurately if moisture is present on the sensor surface after being exposed to high humidity for an extended period. In this situation, allow the product to dry in a dry environment at room temperature and humidity before use.
∗3. Measurement precision may deteriorate due to the adhesion of impurities, contaminants, organic chemical substances, or other environmental matter on the sensor surface during use. Periodic calibration is recommended to check the measurement precision.
∗4. Long-term drift values are based on continuous usage or storage at a temperature of 25°C and a humidity of 20 to 60% within the warranty period of the product. Continuous usage or storage in an environment that exceeds these conditions may result in a drift value greater than the stated value.
∗5. Measurement precision deterioration may occur while the product is in storage. To maintain the original product performance, ensure a storage environment within the recommended temperature and humidity ranges. Storage in an environment that exceeds the specified conditions may cause deterioration of the measurement precision.
Model | ZN-THX11-SA |
---|---|
Sensor that can be connected | Thermo-Humidity Sensor Head (ZN-THS1[][]-S) |
Display | LCD 7-segment 5-digit 2-step display, auxiliary information indicator display |
Measurement interval | 10 s, 20 s, 30 s, 1 min, 2 min, 5 min, 10 min, 20 min, 30 min, 1 h |
Calculation function | Instantaneous value, maximum value, minimum value, average value |
Operating mode | Normal mode, sleep mode *1 |
Recording mode | Continue *2, ring *3 |
Alarm signal output *4 | Output to photocoupler (External power supply: 12 to 24 VDC, Load current: Max. 45
mA) Alarm hold setting is possible. *5 |
Internal storage device | Internal memory: Approx. 8,500 data items |
External storage device | SD card (measured value saving/set value saving and reading),
Recommended SD card: HMC-SD292 (2GB) and HMC-SD492 (4GB) (manufactured by OMRON)*8 |
Power supply voltage | DC input: 24 VDC±10%
Battery: 2 AAA batteries *5 |
Battery life | Approx. 1 year *6 (sleep mode, measurement interval of 10 minutes with 2 AAA
nickel metal hydride batteries, with SD card not inserted) |
Operating temperature range | 0 to 60°C |
Operating humidity range | 20 to 85% (no condensation) |
Weight (packaged) | Approx. 500 g |
Accessories | Instruction Sheet, Startup1 Guide, Alarm output connector *7,
DC cable (straight type) |
last update: February 6, 2023