NJ-Series NJ101 CPU Units
            
        
last update: December 9, 2024
Ask your OMRON representative for the most recent applicable standards for each model.
| Product
 name  | 
Specifications | Model | |||
|---|---|---|---|---|---|
| I/O capacity/Model Standards
 maximum number of configuration Units (Expansion Racks)  | 
Program
 capacity  | 
Memory capacity for
 variables  | 
Number
 of motion axes  | 
||
| NJ101 CPU
 Units ![]()  | 
2,560 points/40 Units
 (3 Expansion Racks)  | 
5 MB | 0.5 MB: Retained during power
 interruption 2 MB: Not retained during power interruption  | 
2 | NJ101-1000 | 
| 0 | NJ101-9000 | ||||
The following accessories come with the CPU Unit.
| Product name | Model | 
|---|---|
| Battery | CJ1W-BAT01 | 
| End Cover | CJ1W-TER01 (must be attached to the right end of the CPU Rack) | 
| End Plate | PFP-M (2 required) | 
| SD Memory Card
 (Flash Memory)  | 
NJ501-[][]20, NJ501-1340, NJ501-R[][][]: HMC-SD492
 NJ101-[][]20: HMC-SD292  | 
One Power Supply Unit is required for each Rack.
| Product name | 
							Power
 supply voltage  | 
							Output
 current  | 
							Output
 capacity  | 
Options | Model | |||
|---|---|---|---|---|---|---|---|---|
| 
							5-VDC
 output capacity  | 
							24-VDC
 output capacity  | 
							Total
 power consumption  | 
							24-VDC
 service power supply  | 
							RUN
 output  | 
							Maintenance
 forecast monitor  | 
|||
| 
							AC Power
 Supply Unit  | 
100 to 240 VAC | 6.0A | 1.0A | 30W | No | Yes | No | NJ-PA3001 | 
| 
							DC Power
 Supply Unit  | 
24 VDC | NJ-PD3001 | ||||||
Note: Power supply units for the CJ-Series cannot be used as a power supply for a CPU rack of the NJ system or as a power supply for an expansion rack.
Select the I/O Control Unit, I/O Interface Unit, Expansion Connecting Cable, and CJ-Series Power Supply Unit.
| Product name | Specifications | Current
 consumption (A)  | 
Model | |
|---|---|---|---|---|
| 5V | 24V | |||
| CJ-Series I/O
 Control Unit ![]()  | 
Mount one I/O Control Unit on the CJ-Series CPU Rack when
 connecting one NJ-Series Expansion Racks. Connecting Cable: CS1W-CN[][]3 Expansion Connecting Cable Connected Unit: CJ1W-II101 I/O Interface Unit Mount to the right of the CPU Unit.  | 
0.02 | ― | CJ1W-IC101 | 
Note: Mounting the I/O Control Unit in any other location may cause faulty operation.
| Product name | Specifications | Current
 consumption (A)  | 
Model | |
|---|---|---|---|---|
| 5V | 24V | |||
| CJ-Series I/O
 Interface Unit ![]()  | 
One I/O Interface Unit is required on each Expansion Rack.
 Connecting Cable: CS1W-CN[][]3 Expansion Connecting Cable Mount to the right of the Power Supply Unit.  | 
0.13 | ― | CJ1W-II101 | 
Note: Mounting the I/O Interface Unit in any other location may cause faulty operation.
| Product name | Specifications | Model | |
|---|---|---|---|
| I/O Connecting
 Cable ![]()  | 
• Connects an I/O Control Unit on NJ-Series CPU Rack
 to an I/O Interface Unit on a NJ-Series Expansion Rack. or • Connects an I/O Interface Unit on NJ-Series Expansion Rack to an I/O Interface Unit on another NJ-Series Expansion Rack.  | 
Cable length: 0.3 m | CS1W-CN313 | 
| Cable length: 0.7 m | CS1W-CN713 | ||
| Cable length: 2 m | CS1W-CN223 | ||
| Cable length: 3 m | CS1W-CN323 | ||
| Cable length: 5 m | CS1W-CN523 | ||
| Cable length: 10 m | CS1W-CN133 | ||
| Cable length: 12 m | CS1W-CN133-B2 | ||
The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.
For details, refer to your local OMRON website and Sysmac Studio Catalog (Cat. No. P138).
            Please download it from following URL and install to Sysmac Studio.
https://www.ia.omron.com/sysmac_library/
        
| Product | Features | Model | 
|---|---|---|
| Vibration Suppression Library | The Vibration Suppression Library is used to suppress
 residual vibration caused by the operation of machines.  | 
SYSMAC-XR006 | 
| Device Operation Monitor Library | The Device Operation Monitor Library is used to
 monitor the operation of devices such as air cylinders, sensors, motors, and other devices.  | 
SYSMAC-XR008 | 
| Dimension Measurement Library | The Dimension Measurement Library is used to
 dimension measurement with ZW-8000/7000/5000 Confocal Fiber Displacement Sensor, or E9NC-TA0 Contact-Type Smart Sensor.  | 
SYSMAC-XR014 | 
            Use a straight STP (shielded twisted-pair) cable of category 5 or higher with double shielding (aluminum tape and braiding) for EtherCAT.
For EtherNet/IP, required specification for the communications cables varies depending on the baud rate.
For 100BASE-TX/10BASE-T, use a straight or cross STP (shielded twisted-pair) cable of category 5 or higher.
For 1000BASE-T, use a straight or cross STP cable of category 5e or higher with double shielding (aluminum tape and braiding).
        
| Item | Recommended
 manufacturer  | 
Cable
 length (m)  | 
Model | |
|---|---|---|---|---|
| Wire Gauge and
 Number of Pairs: AWG26, 4-pair Cable Cable Sheath material: PUR  | 
Cable with Connectors on Both Ends
 (RJ45/RJ45) Standard RJ45 plug type *1 Cable color: Yellow *2 EtherCAT/ EtherNet/IP (10BASE/ 100BASE/1000BASE *4) ![]()  | 
OMRON | 0.3 | XS6W-6PUR8SS30CM-YF | 
| 0.5 | XS6W-6PUR8SS50CM-YF | |||
| 1 | XS6W-6PUR8SS100CM-YF | |||
| 2 | XS6W-6PUR8SS200CM-YF | |||
| 3 | XS6W-6PUR8SS300CM-YF | |||
| 5 | XS6W-6PUR8SS500CM-YF | |||
| Wire Gauge and
 Number of Pairs: AWG22, 2-pair cable  | 
Cable with Connectors on Both Ends
 (RJ45/RJ45) Rugged RJ45 plug type *1 Cable color: Light blue EtherCAT/ EtherNet/IP (10BASE/100BASE) ![]()  | 
OMRON | 0.3 | XS5W-T421-AMD-K | 
| 0.5 | XS5W-T421-BMD-K | |||
| 1 | XS5W-T421-CMD-K | |||
| 2 | XS5W-T421-DMD-K | |||
| 5 | XS5W-T421-GMD-K | |||
| 10 | XS5W-T421-JMD-K | |||
| Cable with Connectors on Both Ends
 (M12 Straight/M12 Straight) Shield Strengthening Connector cable *3 M12/Smartclick Connectors Cable color: Black EtherCAT/ EtherNet/IP (10BASE/100BASE) ![]()  | 
OMRON | 0.5 | XS5W-T421-BM2-SS | |
| 1 | XS5W-T421-CM2-SS | |||
| 2 | XS5W-T421-DM2-SS | |||
| 3 | XS5W-T421-EM2-SS | |||
| 5 | XS5W-T421-GM2-SS | |||
| 10 | XS5W-T421-JM2-SS | |||
| Cable with Connectors on Both Ends
 (M12 Straight/RJ45) Shield Strengthening Connector cable *3 M12/Smartclick Connectors Rugged RJ45 plug type Cable color: Black EtherCAT/ EtherNet/IP (10BASE/100BASE) ![]()  | 
OMRON | 0.5 | XS5W-T421-BMC-SS | |
| 1 | XS5W-T421-CMC-SS | |||
| 2 | XS5W-T421-DMC-SS | |||
| 3 | XS5W-T421-EMC-SS | |||
| 5 | XS5W-T421-GMC-SS | |||
| 10 | XS5W-T421-JMC-SS | |||
| Item | Recommended manufacturer | Model | ||
|---|---|---|---|---|
| Products for
 EtherCAT or EtherNet/IP (1000BASE-T*2/ 100BASETX)  | 
Wire Gauge and
 Number of Pairs: AWG24, 4-pair Cable  | 
Cables | Kuramo Electric Co. | KETH-SB *1 | 
| RJ45
 Connectors  | 
Panduit Corporation | MPS588-C *1 | ||
| Products for
 EtherCAT or EtherNet/IP (100BASE-TX/ 10BASE-T)  | 
Wire Gauge and
 Number of Pairs: AWG22, 2-pair Cable  | 
Cables | Kuramo Electric Co. | KETH-PSB-OMR *3 | 
| JMACS Japan Co., Ltd. | PNET/B *3 | |||
| RJ45 Assembly
 Connector ![]()  | 
OMRON | XS6G-T421-1 *3 | ||
            *1. We recommend you to use the above Cable and RJ45 Connector together.
*2. The products can be used only with the NX701/NX502
*3. We recommend you to use the above Cable and RJ45 Assembly Connector together.
        
| Item | Specification | Model | 
|---|---|---|
| Memory Cards *1 | SD memory card, 2GB | HMC-SD292 | 
| SDHC memory card, 4GB | HMC-SD492 | |
| SDHC memory card, 16GB | HMC-SD1A2 | 
            *1. There are restrictions on the combination of CPU Unit version and memory card. Refer to NJ/NX-series CPU Unit
    Software User's Manual (W501) 8-5-2 Specifications of Supported SD Memory Cards, Folders, and Files for details.
        
| Product name | Specifications | Model | |
|---|---|---|---|
Battery Set
![]()  | 
Battery for NX701-[][][][]/
 NJ501-[][][][]/NJ301-[][][][]/ NJ101-[][][][] NJ/NX-Series CPU Unit maintenance  | 
Note:
 1. The battery is included as a standard accessory with the CPU Unit. 2. The battery service life is 5 years at 25°C. (The service life depends on the ambient operating temperature and the power conditions.) 3. Use batteries within two years of manufacture.  | 
CJ1W-BAT01 | 
End Cover
![]()  | 
Mounted to the right-hand
 side of NJ-Series CPU Racks or Expansion Racks.  | 
One End Cover is provided as a standard accessory
 with each CPU Unit and I/O Interface Unit.  | 
CJ1W-TER01 | 
last update: December 9, 2024