Smart Proximity Sensor
last update: February 13, 2020
| Model | E2NC-EDR6-F | E2NC-ED01(-[]) | E2NC-ED02(-[]) | E2NC-EM02(-[]) | |
|---|---|---|---|---|---|
| 3 dia. × 18 mm | 5.4 dia. × 18 mm | 8 dia. × 22 mm | M10 × 22 mm | ||
| Sensing Distances | 0.6 mm | 1 mm | 2 mm | 2 mm | |
| Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
| Standard sensing object | 5 × 5 mm | 5 × 5 mm | 10 × 10 mm | 10 × 10 mm | |
| Material: iron (t = 3, S50C) | |||||
| Repeatability *1 | 1 μm | 1 μm | 2 μm | 2 μm | |
| Hysteresis distance | Variable | ||||
| Temperature
characteristics *2 |
Sensor Head | 0.3%/°C | 0.08%/°C | 0.08%/°C | 0.08%/°C |
| Preamplifier
and Amplifier |
0.08%/°C | ||||
| Ambient
temperature range *3 |
Operating | -10°C to 60°C (with no icing or condensation) | |||
| Storage | -10°C to 60°C
(with no icing or condensation) |
-20°C to 70°C (with no icing or condensation) | |||
| Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case | ||||
| Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
| Degree of protection (Sensor
Head) |
IEC60529 IP67 | ||||
| Weight (packed state) *6 | Approx. 120 g | ||||
| Materials | Sensor Head | Brass | SUS | Brass | Brass |
| Sensing surface | Heat-resistant ABS | ||||
| Clamping nut | --- | Nickel-plated
brass |
|||
| Toothed washer | --- | Zinc-plated iron | |||
| Preamplifier | PES | ||||
| Connection method *7 | Connector (Standard models and models with Protective Spiral Tube: The standard
cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.) |
||||
| Accessories | Instruction Manual, Mounting Brackets | ||||
| Model | E2NC-EV05(-[]) | E2NC-EM07M(-[]) | E2NC-EM02H | |
|---|---|---|---|---|
| 30 × 14 × 4.8 mm | M18 × 46.3 mm | M12 × 22 mm | ||
| Sensing Distances | 5 mm | 7 mm | 2 mm | |
| Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
|||
| Standard sensing object | 15 × 15 mm | 22 × 22 mm | 20 × 20 mm | |
| Material: iron (t = 3, S50C) | ||||
| Repeatability *1 | 2 μm | 5 μm | 2 μm | |
| Hysteresis distance | Variable | |||
| Temperature
characteristics *2 |
Sensor Head | 0.04%/°C | 0.08%/°C | 0.2%/°C |
| Preamplifier
and Amplifier |
0.08%/°C | |||
| Ambient
temperature range *3 |
Operating | -10°C to 60°C (with no icing or condensation) | -10°C to 200°C
(with no icing or condensation) *4 |
|
| Storage | -20°C to 70°C (with no icing or condensation) | |||
| Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | |||
| Insulation resistance | 50 MΩ min. (at 500 VDC) | |||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case | |||
| Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
| Degree of protection (Sensor
Head) |
IEC60529 IP67 | IEC60529 IP60 *5 | ||
| Weight (packed state) *6 | Approx. 120 g | |||
| Materials | Sensor Head | Zinc | Brass | Brass |
| Sensing surface | Heat-resistant ABS | PEEK | ||
| Clamping nut | --- | Nickel-plated brass | ||
| Toothed washer | --- | Zinc-plated iron | ||
| Preamplifier | PES | PEEK | ||
| Connection method *7 | Connector (Standard models and models with Protective Spiral Tube: The standard
cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.) |
|||
| Accessories | Instruction Manual, Mounting Brackets | |||
*1. Repeatability: The standard reference object at 1/2 of the measurement range.
*2. Temperature characteristic: The standard reference object at 1/2 of the measurement range.
*3. Do not expose the product to rapid temperature changes, otherwise the characteristics may be deteriorated.
*4. Sensor Head only (The ambient temperature of other parts is -10 to 60°C)
*5. Do not expose the product to steam. This product does not have any protection mean against water.
*6. The protective spiral tube adds another 90 g to the weight.
*7. Standard length is the length containing the preamplifier and connector.
| Types | Advanced models | Model for Sensor
Communications Unit *1 |
||||
|---|---|---|---|---|---|---|
| NPN output | E2NC-EA21 | E2NC-EA7TW | E2NC-EA7 | E2NC-EA10 | E2NC-EA0 | |
| PNP output | E2NC-EA51 | E2NC-EA9TW | E2NC-EA9 | E2NC-EA40 | ||
| Connecting method | Pre-wired
(2 m) |
Wire-saving Connectors | Connector for
Sensor Com- munications Unit Pre- wired (2 m) |
Connector for
Sensor Com- munications Unit |
||
| Input/
output |
Output | 2 outputs | 1 output | 1 output *2 | 2 outputs *3 | |
| External
inputs *4 |
1 input | --- | 1 input | --- | --- | |
| Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Refer to the communication unit
specifications. |
||||
| Power consumption *5 | At Power Supply Voltage of 24 VDC
Normal mode: 1,080 mW max. (Current consumption at 45 mA max.), Eco function ON: 840 mW max. (Current consumption at 35 mA max.), Eco function LO: 960 mW max. (Current consumption at 40 mA max.) |
|||||
| Control output | Load power supply voltage: 30 VDC max., open collector output
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. |
Refer to the
communication unit specifications. |
||||
| Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), ST indicator (blue) and OUT selection indicator (orange, only on models with 2 outputs) |
|||||
| Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection | Power supply
reverse polarity protection, output short-circuit protection |
||||
| Response
time |
Super-high-
speed mode (SHS) |
Operate or reset: 150 μs | ||||
| High-speed
mode (HS) |
Operate or reset: 300 μs (default setting) | |||||
| Standard
mode (Stnd) |
Operate or reset: 1 ms | |||||
| GIGA power
mode (GIGA) |
Operate or reset: 4 ms | |||||
| Sensitivity adjustment | Smart Tuning (Fine Positioning, 2-point Tuning, Position Tuning, Percentage Tuning (-99% to
99%), Full Auto Tuning, or manual adjustment |
|||||
| Maximum connectable
Units |
16 units | With E3NW-ECT:
30 units *6 With E3NW-CCL: 16 units |
||||
| No. of Units for mutual
interference prevention |
Up to five units, intermittent oscillation method
(response time = (No. of connected units + 1) x 15 ms) Note: The mutual interference prevention function is disabled if Super High Speed mode (SHS) is selected for detection function. |
|||||
| Functions | Operation
mode |
NO (Normally Open)/NC (Normally closed) | ||||
| Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer:
1 to 9,999 ms |
|||||
| Differential
detection |
Single edge: Can be set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. | |||||
| Zero reset | Provided
Zero-reset is accompanied by a change of detection distance. After zero-reset, some threshold level may also cause a change of the indication by influence of other settings. |
|||||
| Resetting
settings *7 |
Select from initial reset (factory defaults) or user reset (saved settings). | |||||
| Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display
dimmed). |
|||||
| Bank
switching |
Select from banks 1 to 4. | |||||
| Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||||
| Output 2 | Select from normal detection
mode, alarm output mode, error output mode or disconnection detection output mode. |
--- | --- | Select from
normal detection mode, alarm output mode, error output mode or disconnection detection output mode. |
||
| External
input |
Select from input
OFF, 2-point Tuning, Percent- age Tuning, Full Auto Tuning, Fine Positioning, zero reset, synchronization detection, or bank switching. |
--- | Select from input
OFF, 2-point Tuning, Percent- age Tuning, Full Auto Tuning, Fine Positioning, zero reset, synchronization detection, or bank switching. |
--- | --- | |
| Hysteresis
width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be
set from 0 to 9,999. |
|||||
| Changing
the displays |
Threshold/Detected intensity ratio, Peak receiving
Detected amount/Bottom Detected amount, Threshold bar display, Peak Detected amount/ Receiving Detected and CH number/Detected amount |
Threshold/ Detected intensity ratio,
Peak receiving Detected amount/ Bottom Detected amount, Threshold bar display, Peak Detected amount/ Receiving Detected and CH number/ Detected amount |
||||
| Ambient temperature
range |
Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||||
| Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air
temperature range shown above |
|||||
| Altitude | 2,000 m max. | |||||
| Installation environment | Pollution degree 3 | |||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||||
| Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
| Shock resistance
(destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y,
and Z directions |
||||
| Weight (packed state/
Sensor only) |
Approx. 115 g/
Approx. 75 g |
Approx. 60 g/
Approx. 20 g |
Approx. 60 g/
Approx. 20 g |
Approx. 95 g/
Approx. 45 g |
Approx. 65 g/
Approx. 25 g |
|
| Materials | Case | Polycarbonate (PC) | ||||
| Cover | Polycarbonate (PC) | |||||
| Cable | PVC | |||||
| Accessories | Instruction Manual | |||||
| Contact input (relay or switch) | Non-contact input (transistor) | Input time
*4-1 |
|
|---|---|---|---|
| NPN output
E2NC-EA21 E2NC-EA7 |
ON: Shorted to 0 V (Sourcing current:
1 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min.
OFF: 20 ms min. |
| PNP output
E2NC-EA51 E2NC-EA9 |
ON: Shorted to Vcc (Sinking current:
3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA
max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
last update: February 13, 2020